4
Measuring wire
Battery
Adapter
Tester
File clip
Lip hook
Touch probe
1.5 Package includes
Page 1: ...Apex Locator Instruction for Use...
Page 2: ...8 5 Dental Operation with Device for reference 12 6 Trouble Shooting 17 7 Cleaning Disinfection and Sterilization 21 8 Maintenance 27 9 Environmental Protection 28 10 Symbol Instruction 28 11 Statemen...
Page 3: ...x locator is a supporting device for endodontic treatments Through determining the position of apical constriction and the length of the root canal space will help dentists complete endodontic treatme...
Page 4: ...4 Measuring wire Battery Adapter Tester File clip Lip hook Touch probe 1 5 Package includes...
Page 5: ...5 Diagram of components and control buttons...
Page 6: ...be operated with battery only Detach adapter from the device for operation Remove battery from device for long term storage The device cannot be autoclaved Use disinfectant of neutral pH value or ethy...
Page 7: ...battery icon with full bars Warning Do not use device on patient while charging 3 2 Lip hook and file clip The measuring wire has a plug at one end and two jacks on the other end Plug in the measurin...
Page 8: ...the connecting wire from ApexPilot G2 The screen on A2 will show icon connecting the endo motor For detail setting and functions refer to ApexPilot G2 manual Apex Locator section 4 Device Operation 4...
Page 9: ...e display screen shows a bar ranging from all white and advances to blue orange and then red Icon at the top shows the hook and clip are touching If the hook and clip are touching there will be contin...
Page 10: ...e display screen shows the tooth and the file extending to the bottom White zone When the file reaches near the bottom the enlarged display of apical foramen starts to light up the white bar and the d...
Page 11: ...to check the position with an x ray Note The recommended working length is between 0 5 and 1 0 mm blue zone But it varies across different teeth Dentist should make professional judgement during opera...
Page 12: ...e health bridge or on the tooth filled integrated The position of the mark should be on the incisal edge of the anterior tooth or on the spire of the molars For those bridge that s broken obviously th...
Page 13: ...ssue of the gingival may reach the cavity of the endo hole at the broken point which will cause inaccuracy because of the electronic conduction The measurement can be continued when the crown is fixed...
Page 14: ...mal or that the photo was taken incorrectly The actual position of the apical foramen is different from the anatomical one It is very common that the apical foramen is slightly to the side of the root...
Page 15: ...hook and the file clip 5 Hang the lip hook on the lip make sure it makes contact with the oral mucosa as a reference electrode 6 Clip the file with file clip approach to the apex then there will be co...
Page 16: ...ber piece set on the endo file to the reference point incisal edge or fossa edge then pull out the endo file measure the length between the top of the file and the rubber piece and this is the working...
Page 17: ...m the measuring wire is plugged firmly link the lip hook with the file clip to check if the measuring wire is broken No sound of alarm Volume is set at mute Adjust the sound level The charging LED ind...
Page 18: ...l is filled with blood or other liquid Once the endo needle contact the surface of the root canal which is filled with blood liquid it will display OVER immediately In this case push the needle to the...
Page 19: ...nt measurement from the gums to the periodontal tissue loss the screen will display OVER Adjacent surface has caries Current measurement flow from caries of the adjacent surface to gums then the root...
Page 20: ...suring wire is broken or has poor contact Contact both ends of the measuring wire directly it displays 3 The length measurement indicator only full display near narrow part of the apical The root cana...
Page 21: ...7 1 1 Processing principles It is only possible to carry out effective sterilization after the completion of effective cleaning and disinfection Please ensure that as part of your responsibility for...
Page 22: ...eferred if conditions permit Automated cleaning The cleaner is proved to be valid by CE certificationin accordance with EN ISO 15883 There should be a flushing connector connected to the inner cavity...
Page 23: ...infector inspect refer to section Inspection and Maintenance and packaging refer to chapter Packaging Dry the product repeatedly if necessary refer to section Drying Note 1 Before use you must careful...
Page 24: ...maximum pressure 3 bar Until no liquid is sprayed onto the white paper white cloth the product drying is completed 2 It can also be dried directly in a medical drying cabinet or oven The recommended d...
Page 25: ...s at a temperature of 132 C 134 C and a pressure of 2 0 bar 2 3 bars 4 Allow a maximum sterilization time of 20 minutes at 134 C Verification of the fundamental suitability of the products for effecti...
Page 26: ...s 1 The storage environment should be clean and must be disinfected regularly 2 Product storage must be batched and marked and recorded 7 10 Transportation Prevent excessive shock and vibration during...
Page 27: ...the original lithium battery 1 Turn off device 2 Remove the battery cover 3 Remove the old battery and disconnect the connector 4 Connect the new battery and put it in the Battery compartment 5 Put ba...
Page 28: ...Instructions for Use Serial number Date of manufacture Manufacturer Type BF applied part Class II equipment Ordinary equipment Recovery Used indoor only Power on off Sound adjustment Apical Stop Setti...
Page 29: ...t for components not warranted under Exclusions that are defective in material or workmanship under normal use and service BEYES obligation under this limited warranty is limited to the repair or repl...
Page 30: ...by natural or artificial light 10 Custom manufactured products 11 Alterations or modifications to the product by any person or entity other than BEYES 12 Products that would otherwise by covered under...
Page 31: ...ninety 90 days following expiration of the limited warranty period 13 Technical Specification Technical parameters Device Classification Class II Type B IPX0 Applied part touch probe lip hook file cl...
Page 32: ...or use in the electromagnetic environment specified below The customer or the user of the model should assure that it is used in such an environment Emissions test Compliance Electromagnetic environme...
Page 33: ...kV contact 8 kV air 6 kV contact 8 kV air Floors should be wood concrete or ceramic tile If floors are covered with synthetic material the relative humidity should be at least 30 Electrical fast trans...
Page 34: ...in UT for 5 sec Voltage should be that of a typical commerc1al or hospital environment If the user of the model require continued operation during voltage interruptions it is recommended that the mode...
Page 35: ...closer to any part of the model including cables than the recommended separation distance calculated from the equation applicable to the frequency of the Transmitter Recommended separation distance d...
Page 36: ...ich the model is used exceeds the applicable RF compliance level above the model should be observed to verify normal operation If abnormal performance is observed additional measures may be necessary...
Page 37: ...o the transmitter manufacturer NOTE 1 At 80 MHZ and 800 MHZ the separation distance for the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propa...
Page 38: ...with Beyes Dental Canada Inc claims compliance with the requirements of Emission and Immunity Please use original accessories 4 The use of accessories transducers and cables other than those specifie...
Page 39: ...39...
Page 40: ...aplein 10 Ie Verd 2595AA The Hague Netherlands Tel 31645171879 English 31626669008 Dutch Email info beyes ca Website www beyes ca Printed in Canada ENI038 Rev 1 26 04 21 Federal law restricts this dev...