SAFETY INFORMATION
DANGER: Failure to follow the dangers, warning and cautions in this manual may in result
in serious bodily injury or death, or in a fire or an explosion causing damage to property.
The installation and repairs of this appliance must
conform with local codes or, in the absence of local
odes, with either the National Fuel Gas Code, ANSI
Z223.1/NFPA 54, or Natural Gas and Propane
Installation Code, CSA/CGA-B149.1.
All pipe sealants must be an approved type and
resistant to the actions of L.P. gases. Never use pipe
sealant on flare fittings. All gas connections should be
made by a competent qualified service technician and
in accordance with local codes and ordinances. In the
absence of local codes, the installation must comply
with the National Fuel Gas Code, NFPA 54-2002/ANSI
Z223.1-2002.
This grill must be isolated from the gas supply piping
system by closing its individual manual shut-off valve
during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 PSI
(3.5 kPa.).
This grill is intended for use outdoors and should not
be used in a building, garage or any other enclosed or
covered area.
A minimum clearance of 24 inches from combustible
constructions to the sides of the grill and 24 inches
from the back of the grill to combustible constructions
must be maintained. This outdoor cooking gas
appliance must not be placed under overhead
combustible construction.
Natural Gas (NG) Characteristics:
a. NG is flammable and hazardous if handled
improperly. Become aware of the characteristics
before using any NG products.
b. NG is explosive under pressure, heavier than air and
settles and pools in low areas.
c. NG in its natural state has no odor. For your safety,
an odorant is added than smells like rotten cabbage.
d. Contact with NG can cause freeze burns to skin.
Do not block holes in sides or back of the grill.
A fire causing, serious bodily injury or damage to
property may occur if above is not followed exactly.
The use of alcohol, prescription or non- prescription
drugs may impair the consumers’ ability to properly
assemble or safely operate the appliance.
Never use charcoal, lighter fluid, lava rocks, gasoline,
kerosene or alcohol with this product.
Check for leaks even if your unit was assembled for
you by someone else.
Do not operate if gas leak is present. Gas leaks may
cause a fire or explosion.
You must follow all leak-checking procedures before
operating. To prevent fire or explosion hazard when
testing for a leak:
a. Always perform leak test before lighting the grill and
each time the tank is connected for us.
b. No smoking. Do not use or permit sources of
ignition in the area while conducting a leak test.
c. Conduct the leak test outdoors in a well-ventilated
area.
d. Do not use matches, lighters, or a flame to check for
leaks.
e. Do not use grill until any and all leaks are corrected.
If you can unable to stop a leak, turn off the main
valve on the NG supply line. Call a gas appliance
serviceman or your local NG supplier.
Never attach an unregulated gas line to the appliance.
Connection to an unregulated gas line can cause
excessive heat or fire.
The appliance and its individual shutoff valve must be
disconnected from the gas supply piping system
during any pressure testing of that system at
pressures in excess of 1/2 psig (3.5kpa).
The appliance must be isolated form the gas supply
piping system by closing its individual manual shutoff
valve during any pressure testing of the gas supply
piping system at test pressures equal to or less than
1/2 psig (3.5kpa).
Do not store or use gasoline or other flammable
liquids or vapors within 25 feet (7.62 m) of this
appliance.
Do not use in an explosive atmosphere. Keep grill area
clear and free from combustible materials, gasoline
and other flammable vapors and liquids.
It is essential to keep the grill’s valve compartment,
burners and circulating air passages clean.
Use only the gas pressure regulator supplied with this
appliance. This regulator is set for an outlet pressure
of 11.0 wc
The cylinder used must include a collar to protect the
cylinder valve.
Do not store a spare LP-gas cylinder under or near this
appliance.
Do not alter grill in any manner. Any alteration will void
your warranty.
Do not use grill in high winds.
Do not use the grill unless it is COMPLETELY
assembled and all parts are securely fastened and
tightened.
Do not build this model of grill in any built-in or slide in
construction. Ignoring this warning could cause a fire
or an explosion that can damage properly and cause
serious bodily injury or death.
This grill should be thoroughly cleaned and inspected
Clean and inspect the hose before each use of the
appliance. If there is evidence of abrasion, wear, cuts
or leaks, hose must be replaced prior to the appliance
being put into operation.
Use only the regulator and hose assembly provided.
The replacement regulator and hose assembly shall be
that specified by the manufacturer.
on a regular basis.
Use only Chant Kitchen Equipment (H.K.) Ltd.
company authorized parts. The use of any part that is
not company authorized can be dangerous. Doing so
will also void your warranty.
Never fill the cylinder beyond 80 percent full.
Inspect grill before each use.
Do not operate this appliance without reading
“Operating Instructions” in this manual.
This grill is designed with to operate at an inlet
pressure of: LP gas: 11 inches water column; NG
7inches water column.