NATURAL GAS CONVERSION
7,
Remove the 3 main burner control knobs by grasping and pulling out.
Insert slotted screwdriver (Not included) into the hole of each control valve shaft as shown. Rotate the shaft
counterclockwise (to the left) as far as it will go (about 2 complete turns) until it stops. The shaft will now be set in
the NG position. Re-attach the control knobs. Paste the new rating label for NG under the original LP rating label
on the cart door inner panel.
Now NG conversion is completed.
!
CAUTION:
If low flames or burner problems are observed after converting from LPG to NG, the natural gas
lines may not be large enough. Refer to the “From House to Grill” chart on page 5 for natural gas
supply line specifications. Please contact a plumber to assure proper pressure at 7 in. water
column.
DO NOT RETURN YOUR GRILL TO THE STORE.