38
Robusta SC
10.
Overview motorization:
Use of ‘Normal’ motor for up to 30 cycles/day. For more intensive use, the
‘Intensive’ motor is advised.
Motorization: See table below:
(1)
Up to 6m free passage. Use the “844 ER16” motor up to 30 cycles / day
(2)
For more intensive use the “844 ER16” motor. The intensive motor is needed
in case of “dead man” or R2000 more than 6m free passage.
(3)
Safety strips mounted on the guiding post
- two safety strips with single post.
- four safety strips with single post and cabinet.
Two strips on post and two strips on cabinet
Type
Motorization table
Model
500 line
1000 line
Underbeam
R2000
R2800
Application
Normal use
(1)
Normal use
Motor
746 ER16
(2)
844 ER16
Controller Board
780D
780D
Plug-in receiver
866MHz
866MHz
Nr of transmitters
2
2
photocells
XP20W D
XP20W D
Nr. of photocells
2
2
Height photocells
180 / 900mm
180 / 900mm
Warning Light
light 230V LED
light 230V LED
Safety edges
Resisitive ASO 65 ST
Resisitive ASO 65 ST
Nr. of safety edges
on GP
2
(3)
standard
4
(3)
with cabinet
2
(3)
standard
4
(3)
with cabinet
Safety edges on
front wing
Resisitive ASO 65 ST
Resisitive ASO 65 ST
Safety edges on
rear wing
-
-
Wireless
transmission
system
JCM 3G Radioband
JCM 3G Radioband
Summary of Contents for R2000
Page 1: ...1 Robusta SC Cantilever sliding gates Robusta SC Installation Manual ...
Page 11: ...11 Robusta SC 4 1 1 Automatic version right opening ...
Page 12: ...12 Robusta SC 4 1 2 Automatic version left opening ...
Page 13: ...13 Robusta SC 4 1 3 Motorizable version right opening ...
Page 14: ...14 Robusta SC 4 1 4 Motorizable version left opening ...
Page 15: ...15 Robusta SC 4 1 5 Manuel version right opening ...
Page 16: ...16 Robusta SC 4 1 6 Manuel version left opening ...