17
Robusta SC
4.2.
Preparations before gate installation:
Fixing requirements:
•
Chemical anchors M16 x 250 mm with “Fender” type washers (minimum
125 mm anchor depth and minimum 100 mm above finished Ground
Level).
•
For the mounting and securing of:
-
Guiding post (4 anchors)
-
Lock post (4 anchors)
-
Rear guiding roller set (4 anchors)
•
Chemical anchors M10 x 200 mm. 4 anchors for the mounting and
securing of the support roller assembly (when fully open).
WARNING!
DO NOT USE MECHANICAL ANCHORS AS THEY ARE NOT SUITABLE
FOR THIS APPLICATION!
4.3.
Installation of the ground anchors:
1)
Lay a tension line through the central axis of the
foundations to indicate the exact position where the
gate is to be installed. This incorporates the end
post, the guiding post, the rear roller assembly and
the rear support roller.
2)
Install the ground fixations of the guiding and end post
according to the positions indicated on the foundation plan.
Therefore following fixation material is required:
Chemical anchors M16 (minimum 100mm above Finished Ground
Level. For anchor depth check installation manual of supplier
chemical resin).
Betafence does not deliver the chemical anchors.
3)
Mark the position of the holes with
a small diameter concrete drill, his
will help to central the final drill.
4)
Drill the corresponding holes for the fixation
according the installation instructions of the
supplier of the chemical anchors. Drillings
must be in good vertical position.
Summary of Contents for R2000
Page 1: ...1 Robusta SC Cantilever sliding gates Robusta SC Installation Manual ...
Page 11: ...11 Robusta SC 4 1 1 Automatic version right opening ...
Page 12: ...12 Robusta SC 4 1 2 Automatic version left opening ...
Page 13: ...13 Robusta SC 4 1 3 Motorizable version right opening ...
Page 14: ...14 Robusta SC 4 1 4 Motorizable version left opening ...
Page 15: ...15 Robusta SC 4 1 5 Manuel version right opening ...
Page 16: ...16 Robusta SC 4 1 6 Manuel version left opening ...