Part 9
•
Configuration 6:
2 x safeguarding area (SA 1 and SA 2), separate.
1 x safeguarding area (SA 4), cascaded, i. e. the arming areas must be armed one by one,
1 x safeguarding area (SA 3), separate and not integrated into the cascading,
e. g. office complex with two separately safeguarded office rooms and a remote warehouse, etc.
AA 1:
SA 1 (separate safeguarding area) can be armed by AA 1. In the event of an
alarm, the alarm indicators assigned to AA 1 will be activated. However, if AA 4 is
in the armed state alarms will be raised by AA 4.
AA 2:
SA 2 (separate safeguarding area) can be armed by AA 2. In the event of an
alarm, the alarm indicators assigned to AA 2 will be activated. However, if AA 4 is
in the armed state alarms will be raised by AA 4.
AA 4:
SA 4 (cascaded safeguarding area) must only be armed by AA 4 after AA 1 and AA
2 have already been armed. When AA 4 is in the armed state, and in the event of
an alarm, no matter in which safeguarding areas, the alarm indicators assigned to
AA 4 will be activated.
When AA 4 is being disarmed the subordinate arming areas (AA 1 and AA 2) will still
remain armed and must be disarmed separately, if desired.
AA 3:
SA 3 (separate safeguarding area not integrated into the cascading) can be
armed by AA 3. In the event of an alarm, the alarm indicators assigned to AA 3
will be activated.
AA 1
AA 4
AA 2
AA 3
•
Configuration 7.1:
1 x safeguarding area (SA 1), separate.
1 x safeguarding area (SA 4), cascaded, i. e. the arming areas must be armed one by one.
1 x safeguarding area (SA 3), separate and not integrated into the cascading,
e. g. the head's office within an office complex with a separate warehouse and, if necessary, additionally with a
workshop hall, etc.
AA 1:
SA 1 (separate safeguarding area) can be armed by AA 1. In the event of an
alarm, the alarm indicators assigned to AA 1 will be activated. However, if AA 4 is
in the armed state alarms will be raised by AA 4.
AA 4:
SA 4 (cascaded safeguarding area) must only be armed by AA 4 after AA 1 has al-
ready been armed. When AA 4 is in the armed state, and in the event of an alarm,
no matter in which safeguarding areas, the alarm indicators assigned to AA 4 will
be activated.
When AA 4 is being disarmed subordinate AA 1 will still remain armed and must
be disarmed separately, if desired.
AA 3:
SA 3 (separate safeguarding area not integrated into the cascading) can be
armed by AA 3. In the event of an alarm, the alarm indicators assigned to AA 3
will be activated.
AA 1
AA 4
AA 3