background image

 

 

 
 

Thermostat NO contact with centre plate, time-controlled 

 

MAN 

Time-independent control of the room temperature according to the value 
set here 
Activation: 

OK

 

Set temperature: 

+/–

 in the basic display 

Display of function (16): 

MAN

 

TIMER 

Specifying a room temperature for a set number of hours 
Set hours: 

+/– 

Activation: 

OK

 

Display of function (16): 

TIMER

 

Display of time (12): 

xh

 (x = number of remaining hours) 

HOLIDAY 

Specifying a room temperature for a set time period with start and end date 
of the holiday 
The 

AUTO

 function is active until the start of the holiday. Alternatively, the 

AUTO, MAN, TIMER, AT HOME 

functions can be set. 

HOLIDAY

 starts 

when the start date is reached. 
Set 

Year,

 

Month,

 

Day,

 

Temperature

+/–

, confirm each setting by 

pressing 

OK

Activation by confirming the temperature setting: 

OK

 

Display of function (16): 

U.

 

Display of time (12): End date of the holiday in the format DD-MM-YY 

AT HOME 

Temperature control independent of the weekday according to time and 
temperature parameters of the set program (day profile). 
The presettings of the program correspond to the current day program of 
Monday. 
Set temperature and events: 

+/–

, confirm each setting by pressing 

OK

 

Activation with confirmation of the last event 
Display of function (16): 

HOME

 

USER SETTING 

Invoke a settings menu for user settings (see User settings) 
Invoke: 

OK

 

Display of room temperature (15) shows the menu identification - beginning 
with 

G.

 

Scrolled text at the bottom of the display with information about the current 
settings menu 

INSTALLER 
SETTINGS 

Invoking a settings menu for the electrician 
Invoke: 

OK

 (see Information for Electricians – Commissioning) 

Display of room temperature (15) shows the menu identification - beginning 
with 

H.

 

Scrolled text at the bottom of the display with information on the current 
settings menu 

 

Table 1: Overview of the functions and operation 

Setting default values 

Default settings need to be set for some functions e.g. times/temperatures. The value to be set 
then flashes in the display. 
Value flashes. 

„

  Set the default value using the 

+/–

 push-button and press 

OK

 to confirm. 

The new value is saved, the next value to be set flashes. 

 

 
97-09920-000

 

 

Page 7/15 

10/2011

Summary of Contents for 2044 Series

Page 1: ...mpliant with the guidelines of the EN 60730 and works according to the mode of operation 1C Failure to comply with these instructions may result in damage to the device fire or other hazards These ope...

Page 2: ...ater is switched on if the room temperature falls below the preset default value Floor thermostat The floor temperature is controlled The heating is switched on if the room temperature measured by the...

Page 3: ...s using the 9 10 push button if required and press Info OK 11 to confirm Settings The selection of the settings menus is confirmed Carry out further settings with the 9 10 push button and press Info O...

Page 4: ...the morning and night setback Mon Fri Sat Sun Event C C 1 6 00 21 0 7 00 21 0 2 8 30 18 0 10 00 18 0 3 12 00 21 0 12 00 21 0 4 14 00 18 0 14 00 21 0 5 17 00 21 0 17 00 21 0 6 22 00 15 0 Sat 23 00 Sun...

Page 5: ...USER SETTING with push button 9 10 and press OK to confirm see operating thermostat G 1 PROGRAM SELECT ONE is displayed Press OK The number of the active program flashes Using select the desired progr...

Page 6: ...me in the display is saved as the start time of the next interval If flashes in the display then the following event is on the next weekday If OK is pressed the display for the start time changes to t...

Page 7: ...ters of the set program day profile The presettings of the program correspond to the current day program of Monday Set temperature and events confirm each setting by pressing OK Activation with confir...

Page 8: ...e electrician Select YES NO heating off on press OK to confirm Display of function 16 OFF Switch on controller again Select any function via the menu or keep Menu s pressed down for 10 s G5 SUMMER WIN...

Page 9: ...R TEMPERATURE Only when using as floor temperature controller Activating the display of the floor temperature as information number The display C is hidden Factory setting NO normal temperature displa...

Page 10: ...To enable optimum room temperature control using the internal sensor the installation location selected should allow free air circulation not be located behind curtains cupboards shelves etc not be ex...

Page 11: ...ipe so that it can be replaced later The wire of the temperature sensor supplies mains voltage and can be extended to 50 m using suitable wires To avoid signal disturbances do not lay the wire of the...

Page 12: ...Operation H1 APPLICATION Selecting between the thermostat processes according to heating type ROOM Room thermostat FLOOR Floor thermostat LIMITER Room thermostat with limiter Factory settings ROOM Whe...

Page 13: ...ve is opened daily at 10 00 for the time set here in minutes Factory setting 3 min Set opening time press OK to confirm H6 FROST PROTECTION Setting the frost protection mode and temperature When frost...

Page 14: ...itch off voltage and switch on again ERR EXT SENSOR Failure short circuit of the external temperature sensor Replace temperature sensor Display range exceeded fallen short of 6 Appendix 6 1 Specificat...

Page 15: ...vironment It is not possible to enter any data Cause 1 Key lock G6 is active Cancel key lock The desired temperature cannot be set Cause 1 Temperature limit G7 prevents the desired setting Reset tempe...