background image

 

 

 
 

Thermostat NO contact with centre plate, time-controlled 

„

  Select the settings menu 

USER SETTING

 with push-button 

+/–

 (9/10) and press 

OK

 to 

confirm (see operating thermostat). 

G 1 - PROGRAM SELECT ONE 

is displayed. 

„

  Keep pressing the 

+/–

 push-button repeatedly until 

G2 - EVENT SETTING

 is displayed. 

„

  Press 

OK

DAY

 is displayed, the weekday display (14) flashes. 

  Besides individual weekdays, events can also be set for day blocks 1-5, 6-7, 1-7. 1 

corresponds to Monday ... 7 Sunday. 

„

  Select the desired day using the 

+/–

 push-button and press 

OK

 to confirm. 

The temperature display (15) flashes for the first switching interval of the day. 

„

  Set the desired temperature using the 

+/–

 push-button and press 

OK

 to confirm. 

The start time of the switching interval flashes. 

„

  Set the desired start time using the 

+/–

 push-button and press 

OK

 to confirm. 

The end time of the switching interval flashes. 

„

  Set the end time using the 

+/–

 push-button and press 

OK

 to confirm. 

The temperature for the next switching interval flashes. 

  9 events per day are possible. The number of the switching interval is displayed before the 

events. The respective end time in the display is saved as the start time of the next interval. 
If -

>>>

 flashes in the display, then the following event is on the next weekday. If 

OK

 is 

pressed, the display for the start time changes to the start time of next weekday. If 

+/–

 is 

pressed, a further switching interval is created. If all 9 events of a day have been used, the 
program moves automatically to the next weekday. 

  Further temperatures and events can be set similarly if necessary. 

„

  Press 

Menu/

s

 repeatedly to exit the menu item 

G2 - EVENT SETTING

The settings are saved. 

Selecting function 

The device is in the basic display. 

„

  Press 

Menu/

s

 (8) push-button. 

A help text is shown at the bottom of the display (12). 

„

  Keep pressing the 

+/–

 (9/10) push-button repeatedly until the desired menu item (Function 

or Settings menu) is displayed. 

„

  Press 

OK

 (11) push-button. 

The function is activated in the 

AUTO

 and 

MAN

 operating modes. 

In the remaining operating modes/functions, the device returns to further settings (see 
Table 1: Overview of the functions and operation). 

 

Function 

Description 

Operation 

Display 

AUTO 

Control the room temperature according to time and temperature 
parameters of the selected program 
Activation: 

OK

 

Adjust the temperature until the next event: 

+/–

 in the basic display 

Display of function (16): 

AUTO

 

 

 
97-09920-000

 

 

Page 6/15 

10/2011

Summary of Contents for 2044 Series

Page 1: ...mpliant with the guidelines of the EN 60730 and works according to the mode of operation 1C Failure to comply with these instructions may result in damage to the device fire or other hazards These ope...

Page 2: ...ater is switched on if the room temperature falls below the preset default value Floor thermostat The floor temperature is controlled The heating is switched on if the room temperature measured by the...

Page 3: ...s using the 9 10 push button if required and press Info OK 11 to confirm Settings The selection of the settings menus is confirmed Carry out further settings with the 9 10 push button and press Info O...

Page 4: ...the morning and night setback Mon Fri Sat Sun Event C C 1 6 00 21 0 7 00 21 0 2 8 30 18 0 10 00 18 0 3 12 00 21 0 12 00 21 0 4 14 00 18 0 14 00 21 0 5 17 00 21 0 17 00 21 0 6 22 00 15 0 Sat 23 00 Sun...

Page 5: ...USER SETTING with push button 9 10 and press OK to confirm see operating thermostat G 1 PROGRAM SELECT ONE is displayed Press OK The number of the active program flashes Using select the desired progr...

Page 6: ...me in the display is saved as the start time of the next interval If flashes in the display then the following event is on the next weekday If OK is pressed the display for the start time changes to t...

Page 7: ...ters of the set program day profile The presettings of the program correspond to the current day program of Monday Set temperature and events confirm each setting by pressing OK Activation with confir...

Page 8: ...e electrician Select YES NO heating off on press OK to confirm Display of function 16 OFF Switch on controller again Select any function via the menu or keep Menu s pressed down for 10 s G5 SUMMER WIN...

Page 9: ...R TEMPERATURE Only when using as floor temperature controller Activating the display of the floor temperature as information number The display C is hidden Factory setting NO normal temperature displa...

Page 10: ...To enable optimum room temperature control using the internal sensor the installation location selected should allow free air circulation not be located behind curtains cupboards shelves etc not be ex...

Page 11: ...ipe so that it can be replaced later The wire of the temperature sensor supplies mains voltage and can be extended to 50 m using suitable wires To avoid signal disturbances do not lay the wire of the...

Page 12: ...Operation H1 APPLICATION Selecting between the thermostat processes according to heating type ROOM Room thermostat FLOOR Floor thermostat LIMITER Room thermostat with limiter Factory settings ROOM Whe...

Page 13: ...ve is opened daily at 10 00 for the time set here in minutes Factory setting 3 min Set opening time press OK to confirm H6 FROST PROTECTION Setting the frost protection mode and temperature When frost...

Page 14: ...itch off voltage and switch on again ERR EXT SENSOR Failure short circuit of the external temperature sensor Replace temperature sensor Display range exceeded fallen short of 6 Appendix 6 1 Specificat...

Page 15: ...vironment It is not possible to enter any data Cause 1 Key lock G6 is active Cancel key lock The desired temperature cannot be set Cause 1 Temperature limit G7 prevents the desired setting Reset tempe...

Reviews: