Thermostat NO contact with centre plate, time-controlled
Figure 7: Mounting
Align insert (7) in the connector socket and fix it into position with fastening screws (20).
Mount the insert in such a way that the plastic tongue (19) acts as insulation for the
fastening screw. (Figure 7)
Mount the design frame (5) and fix it into position by attaching the operating unit (3).
Connecting external temperature sensor
An external temperature sensor is required for the thermostat process of the floor thermostat
and thermostat with limiter. It is advisable to lay the temperature sensor in a protective pipe so
that it can be replaced later.
The wire of the temperature sensor supplies mains voltage and can be extended to 50 m
using suitable wires.
To avoid signal disturbances, do not lay the wire of the temperature sensor together with
mains cables.
Strip a maximum of 8 mm from the temperature sensor wire.
Connect temperature sensor according to connection diagram (Figure 6, 18).
Figure 8: Terminal for connecting the temperature sensor
When using flexible wire, insert and remove the wire release button (21) with an
appropriate tool.
5.2
Commissioning
CAUTION!
Malfunction of the heating system with incorrect controller settings.
The heating system could get damaged.
Only allow settings of the heating system to be carried out by a skilled specialist.