Thermostat NO contact with centre plate, time-controlled
Selecting and changing programs
The control provides three preset time temperature programs
Program 1
6:00 h
8:00 h
10:00 h
12:00 h
14:00 h
16:00 h
18:00 h
20:00 h
22:00 h
Mon – Fri
Sat – Sun
Figure 3: Time temperature diagram (day profile) for program 1
Program with six events and temperature setback to 18 °C in the morning and afternoon of
working days (absence). At the weekend temperature setback in the morning and night setback.
Mon – Fri
Sat – Sun
Event
Ã
°C
Ã
°C
1 6:00 21.0 7:00 21.0
2 8:30
18.0
10:00
18.0
3
12:00 21.0 12:00 21.0
4
14:00 18.0 14:00 21.0
5
17:00 21.0 17:00 21.0
6 22:00
15.0
Sat:
23:00
Sun: 22:00
15.0
Program 2
6:00 h
8:00 h
10:00 h
12:00 h
14:00 h
16:00 h
18:00 h
20:00 h
22:00 h
Mon – Fri
Sat – Sun
Figure 4: Time temperature diagram (day profile) for program 2
On weekdays like program 1. At the weekend an event for comfort temperature during the
whole day and night setback.
Mon – Fri
Sat – Sun
Event
Ã
°C
Ã
°C
1 6:00 21.0 7:00 21.0
2 8:30 18.0
3 12:00
21.0
4 14:00
18.0
5 17:00
21.0
6 22:00
15.0
Sat:
23:00
Sun: 22:00
15.0
97-09920-000
Page 4/15