2-11
Electrical Installation
88
88A
85
86A
86B
Connect Battery Management System
to Battery Separator Solenoid
This 3
wire harness from the 8 pin connector
routes to the battery separator solenoid.
Cut wires to length, crimp snap fork
terminals on each wire and connect to
designated
terminals.
This
switch
separates the Aux batteries from the
starting batteries. It closes when the truck
batteries are at or above 13.2 and opens at
12.5 volts. Location can be in the AUX
battery box, truck starting battery box or
the supplied plastic enclosure.
This harness must be loomed.
Notice: the terminal connecting points
are printed on each wire.
Terminals are marked as:
88 – Starting battery cable (POS)
88A – Aux battery cable (POS)
85 – Solenoid common (White wire)
86A – solenoid disengage (Tan wire)
86B – solenoid engage (Orange wire)
19
Orange
White
Tan
Summary of Contents for NITE Phoenix
Page 21: ...Section 2 Electrical Installation Rev 9 25 2013 ...
Page 39: ...2 18 Electrical Installation ...
Page 42: ...Section 3 ESPAR Fuel Operated Heater Installation ...
Page 53: ...Section 4 WEBASTO Fuel Operated Heater Installation ...
Page 56: ...5 1 External Wiring Diagram Use for units manufactured after 2 08 2012 ...
Page 57: ...5 2 Internal Wiring Diagram Use for units manufactured after 2 08 2012 ...
Page 58: ...5 3 External Wiring Diagram Use for units manufactured prior to 2 08 2012 ...
Page 59: ...5 4 Internal Wiring Diagram Use for units manufactured prior to 2 08 2012 ...
Page 60: ...Section 6 Operating Instructions ...
Page 64: ...Section 7 Battery Management System BMS Installation ...
Page 65: ...7 1 Battery Management Bergstrom NITE System BMS 100 Installation ...
Page 66: ...7 2 Battery Management ...
Page 67: ...7 3 Battery Management ...