9
GENERAL
8 location of sensors
B
IDRA DS
storage cylinders are equipped with dedicated sockets for the storage cylinder TEMPERATURE GAUGE
or TEMPERATURE SENSOR.
b
The installer is responsible for making all necessary connections to the boiler and solar collectors. Installers must use
their expertise to ensure proper installation and functioning in compliance with all applicable legislation.
B
A
Psc
Pau
Psr
C
A
Temperature sensor socket
B
Temperature sensor
C
Guide
Psc
Boiler temperature sensor socket
Pau
Auxiliary temperature sensor socket
Psr
Solar controller temperature sensor socket
b
Joins between temperature sensor cables and control panel extension cables must be soldered and protected by
sheaths or other forms of electrical insulation.