GENERAL
7 Water circUit
TYPICAL WATER SYSTEM SCHEMATIC
°C
M
10
10
10
6
7
9
8
12
11
13
PS
5
16
2
18
R
M
4
3
UAC
EAF
MC
RC
1
1
9
8
10
10
10
10
7
15 14
17
19
MI Dir
MI Mix
RI Mix
PR
10
10
16
SB1
SB2
SCo
PD
22
16
10
16
10
16
10
10
10
10
10
21
10
21
RI Dir
10
10
20
PB
Solar regulator
Boiler
Water control system
1
Solar collector
2
Collector temperature sensor socket
3
Manual bleed valve
4
Vent cock
5
Vent valve
6
Pressure gauge
7
Safety valve
8
Drain
9
Expansion vessel
10
Disconnect valves
11
Temperature gauge
12
Flow regulator
13
Flow meter
14
Pressure reducer
15
Water softener filter
16
Non-return valve
17
Thermostatic mixer valve
18
Solar storage cylinder
19
DHW recirculation temperature sensor
20
Central heating system pump
21
Central heating system manifolds
22
Mixer valve
UAC
Domestic hot water outlet
EAF
Domestic cold water inlet
MI Mix
Mixed central heating flow
RI Mix
Mixed central heating return
MI Dir
Direct central heating flow
RI Dir
Direct central heating return
MC
Outlet from boiler
RC
Return to boiler
M
Collector outlet
R
Collector return
PI Mix
Mixed central heating pump
PB
Solar storage cylinder heating pump
PR
DHW recirculation pump
PD
Direct central heating pump
PS
Solar collector circuit pump
SB1
Storage cylinder top temperature sensor
SB2
Storage cylinder bottom temperature sensor
SCo
Collector probe
Note! The above schematic is purely indicative.
b
B
IDRA DS
storage cylinders are delivered without a boiler heating pump. A suitably rated pump must be provi-
ded and installed separately. Flow rate from the solar collector circuit depends on the type and number of collectors
installed. For further information, consult the manual for the collectors.
b
The domestic hot water system MUST INCLUDE an expansion vessel, safety valve, automatic vent valve and sto-
rage cylinder drain cock.
b
Safety valves must be connected to a suitable collection and drain system. The manufacturer declines all responsi-
bility for damage caused by water escaping from safety valves.
b
The choice of system components and the method of their installation are left up to the heating engineer installing
the system. Installers must use their expertise to ensure proper installation and functioning in conformity to all ap-
plicable legislation.
b
Circuits filled with anti-freeze must be fitted with water disconnectors.