10
3.0 Mechanical Specification
3.1 Dimensions
278 x 219.5 x 94 mm (L x W x H)
3.2 Weight
2500g ± 100g
3.3 Security Slot
Kensington compatible slot 150N break away force
3.5 Lens Cover
Detached Lens Cover
3.6 Feet
Fast adjustable foot in front, Adjustable foot and Fixed foot in
rear. foot Tilt:0-6
∘
,right/left: +2.2
∘
/-0.5
∘
4.0 Packaging
Detail refer to C309 (Packing Description)
4.1 Outside Dimensions
365 x 230 x 325mm (L x W x H)
4.2 Weight
<5.5 Kg (Including Accessories, Projector).
4.3 Palletization
A type 24,B type 36 by Air; 2016 / 40’ container, or 1008/20’
container by sea
5.0 Thermal Specification
Mechanical component temperature at ambience 0~40
℃
5.1 Surface held or touched
for short periods
Normal surface:
Metal < 60
°
C; Plastic<85
°
C
Bottom surface: @ 25
°
C
Metal < 55
°
C; Plastic<70
°
C
Metal Plastic
5.2 Surface which may be
touched
<70
°
C <95
°
C
5.3 Exhaust Air
<95
°
C
6.0 Environmental
Adhere to Appendix B
Operating
0~40
°
C, without condensation
6.1 Temperature
Storage
-20~60°C, without condensation
Operating
10~90%RH, without condensation
6.2 Humidity
Storage
10~90%RH, without condensation
Summary of Contents for Mainstream MP611
Page 32: ...32 Figure 1 Major Blemish Two Zone Screen Non Critical Zone Critical Zone center 25 ...
Page 43: ...43 Packing ...
Page 44: ...44 ...
Page 61: ...61 Disassembly Assembly Exploded View ...
Page 62: ...62 ...
Page 63: ...63 ...
Page 64: ...64 Disassembly Assembly ...
Page 65: ...65 ...
Page 66: ...66 ...
Page 67: ...67 ...
Page 68: ...68 Level 1 Cosmetic Appearance Alignment Service Appearance ...
Page 69: ...69 ...
Page 70: ...70 ...
Page 71: ...71 ...
Page 78: ...78 Overfill adjustment As the picture below adjust light pipe to keep overfill image center ...
Page 84: ...84 ...
Page 90: ...90 Figure 4 6 Figure 4 9 ...
Page 91: ...91 ...
Page 92: ...92 ...
Page 99: ...99 BKT Link Lamp Shield CW Figure9 3 Figure9 4 ...
Page 104: ...104 3 Example ...
Page 105: ...105 10 Mechanical Assembly Concerns ...
Page 112: ...112 ...
Page 113: ...113 11 Power Assembly Concerns 1 Power board component add GP glue 1 1 CY604 CY605 add glue ...
Page 114: ...114 1 2 CY625 CY612 add glue ...
Page 115: ...115 ...
Page 116: ...116 1 3 C651 R651 add glue 2 SW2 solder by operator ...
Page 121: ...121 ...
Page 122: ...122 ...
Page 124: ...124 ...
Page 128: ...128 Chapter 3 Power Supply Trouble Shooting Guide 1 2 ...
Page 142: ...142 Bridge converts the AC input into DC output and the CAP is AC filter ...
Page 149: ...149 Circuit Schematics ...
Page 150: ...150 ...
Page 151: ...151 ...
Page 152: ...152 PCB Artwork ...
Page 153: ...153 ...
Page 154: ...154 ...
Page 155: ...155 ...
Page 156: ...156 ...
Page 157: ...157 ...
Page 158: ...158 ...
Page 159: ...159 ...
Page 160: ...160 ...
Page 168: ...168 ...