15
SEAR
The intervention threshold of the anti-crashing device (Encoder) during braking is ad-
justed *.
0:Off-1:minimum sensitivity - 99: maximum sensitivity
0-99-(0%)
tinc
This parameter is enabled only for motors equipped with Encoder.
The encoder inhibition is regulated near the opening and closing mechanical stop-
pers.
1: minimum distance – 250: maximum distance
1-250-(250)
* WARNING: AN INCORRECT SETTING OF THESE PARAMETERS MAY RESULT IN AN HAZARD.
COMPLY WITH REGULATIONS IN FORCE!
With motors without limit switch and/or encoder it adjusts the sensitivity of the sensor which causes arrest during slowing
phase.
** 1: minimum force/torque - 99: maximum force/torque
LOGIC (
LOG
)
MENU
FUNCTION
ON-OFF-(Default)
MEMO
TCA
Enables or disables automatic closing
On: automatic closing enabled
Off: automatic closing disabled
(ON)
IbL
Enables or disables condominium function.
On: condominium function enabled. The step-by-step impulse or transmitter impulse
has no effect during the opening phase.
Off: condominium function disabled.
(OFF)
SCL
Enables or disables rapid closing
On: rapid closure is enabled. With open gate, or in the opening phase, the activation
of the photocell causes the automatic closure 3sec after the total opening of the gate.
It is activated only with TCA:ON
Off: rapid closing disabled.
(OFF)
PP
Selects the operating mode of the ”Step by step button” and of the transmitter.
On: Operation: OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
(OFF)
PRE
Enables or disables pre-blinking.
On: Pre-blinking enabled. Blinking is activated 3s before the motor starts.
Off: Pre-blinking disabled.
(OFF)
Blco
Enables or disables the block function in opening.
On: Block function enabled.
To use only with motors equipped with Limit switch.
After the intervention of the opening Limit switch the control unit delays arrest by about
0.5s, so to allow a better strike of the shutter on the stop locks.
Off: Block function disabled
(OFF)
Blcc
Enables or disables the block function in closing.
On: Block function enabled.
To use only with motors equipped with Limit switch.
After the intervention of the opening Limit switch the control unit delays arrest by about
0.5s, so to allow a better strike of the shutter on the stop locks.
Off: Block function disabled.
(OFF)
1mot
The operating mode with 1 or 2 motors is selected:
On: The motor operation is synchronised. This function must be used in the following
cases:
- for each single motor, connect it to M1: Terminals 1/2.
- for two synchronised motors (e.g. balancing doors), connect one motor to M1: terminals
1/2 and the other to M2: terminals 3/4. Adjust the parameters related to motor 1, the
M2 limit switch inputs are deactivated. TDMO and TDMC must be 0.
Off: For two non-synchronised motors, e.g. overlapping gate leaves, adjust TDMO and
TDMC on the desired values.
(OFF)
Cvar
The code programmable transmitters is enabled or disabled.
On: Radio receiver enabled only for rolling-code transmitters.
Off: Receiver enabled for rolling-code and programmable code transmitters (self-
learning and Dip Switch).
(OFF)
OPCL
PP input as OPEN and PED input as CLOSED are enabled or disabled.
On: PP input is enabled as OPEN and PED input is enabled as CLOSED.
Off: PP and PED inputs are enabled with their function.
(OFF)
2ch
Enables or disables the second radio channel on terminals 9/10.
On: Exit configured with function as second radio channel.
Off: Exit takes on function of service light (see Fig.3).
(OFF)