PL-6000DC Two Post Parking Lift
48
P/N 5900273 — Rev. A1 — May 2022
Contact an Electrician
Connecting the Lift to the electrical system requires a certified and licensed Electrician.
⚠
DANGER
All wiring
must
be performed by a licensed, certified Electrician in accordance with
all applicable national and local electrical codes.
Important:
The Lift components do not include a Power Disconnect Switch. When you contact
the Electrician advise them that a UL-Listed Power Disconnect rated for 220 VAC,
25 Amps minimum is required.
The Electrician is required to:
•
Install a Power Disconnect Switch
. The Power Disconnect Switch ensures the operator can
quickly and completely interrupt power to the Lift in the event of an electrical fault, emergency
situation or when the Lift is undergoing service. The Disconnect Switch must be installed within
sight and reach of the Lift Operator. Refer to
Install the Power Disconnect Switch
information.
•
Install a Thermal Disconnect
. Ensures the equipment shuts down in the event of an overload
or an overheated motor. Refer to
Install a Thermal Disconnect Switch
for more information.
The motor on the Power Unit is not thermally protected
.
•
Connect the Power Unit to a 220 VAC power source
•
Wire the Power Unit Junction Box
. Make the connections in the Junction Box including the
controls to raise and lower the Lift Platform, the Limit Switch, the Lowering Solenoid, and Power
both to and from the Power Disconnect to the Power Unit. Refer to
The Electrician must provide:
•
A UL Approved Power Disconnect Switch and mount the switch on the Lift.
•
A Thermal Disconnect (the power unit’s motor is
not
thermally protected).
•
An appropriately sized cord grip for the Limit Switch wiring and creating an opening in the Power
Unit’s Junction box.
•
Wire of the appropriate gauge for the voltage, current and distance to the Lift. As well as conduit to
protect and route the wiring to the Lift from the Electrical service protected by an appropriate
circuit breaker.
Install the Power Disconnect Switch
⚠
DANGER
All wiring
must
be performed by a licensed, certified Electrician in accordance with
all applicable national and local electrical codes. Do not perform any maintenance
or installation on the Lift without first verifying that main electrical power has been
disconnected from the Lift and cannot be re-energized until all procedures are
complete.
⚠
DANGER
Verify the Lift is resting on a Safety Lock or on the ground
before
performing any
maintenance. Do not work on the Lift if the Safety Locks are not engaged, you
could be injured or killed.
⚠
WARNING
A Power Disconnect Switch is not provided with this equipment.
Summary of Contents for PL-6000DC
Page 12: ...PL 6000DC Two Post Parking Lift 12 P N 5900273 Rev A1 May 2022 Typical Height Requirements ...
Page 20: ...PL 6000DC Two Post Parking Lift 20 P N 5900273 Rev A1 May 2022 Drawing not to scale ...
Page 31: ...PL 6000DC Two Post Parking Lift 31 P N 5900273 Rev A1 May 2022 Drawing not to scale ...
Page 70: ...PL 6000DC Two Post Parking Lift 70 P N 5900273 Rev A1 May 2022 Drawing not to scale ...
Page 73: ...PL 6000DC Two Post Parking Lift 73 P N 5900273 Rev A1 May 2022 Labels ...
Page 74: ...PL 6000DC Two Post Parking Lift 74 P N 5900273 Rev A1 May 2022 ...
Page 75: ...PL 6000DC Two Post Parking Lift 75 P N 5900273 Rev A1 May 2022 ...
Page 80: ...PL 6000DC Two Post Parking Lift 80 P N 5900273 Rev A1 May 2022 ...
Page 84: ...PL 6000DC Two Post Parking Lift 84 P N 5900273 Rev A1 May 2022 Maintenance Log ...
Page 85: ...PL 6000DC Two Post Parking Lift 85 P N 5900273 Rev A1 May 2022 Maintenance Log ...
Page 86: ...PL 6000DC Two Post Parking Lift 86 P N 5900273 Rev A1 May 2022 Maintenance Log ...
Page 87: ...PL 6000DC Two Post Parking Lift 87 P N 5900273 Rev A1 May 2022 Maintenance Log ...