Planning for Electrical Work
You will need to have a licensed, certified Electrician available at some point during the installation.
Notify your Electrician in advance
so that they come prepared with appropriate wiring for
connecting the Power Unit to the power source, through a Power Disconnect Switch, and are
prepared to wire the, Junction Box, and Solenoid. Refer to
information.
NOTICE
Power wiring to the Lift as well as the Disconnect Switch itself must be provided by
the Electrician; it is
not
supplied with the Lift.
⚠
DANGER
All wiring
must
be performed by a licensed, certified Electrician. Verify all electrical
work conforms to all applicable local and federal codes, rules and regulations, such
as state and federal OSHA regulations and electrical codes.
The Electrician needs to:
•
Connect a 220 VAC power source
to the Power Disconnect Switch and to the Junction Box.
•
Connect the Junction Box Wiring
. The Junction Box is the connection point for the controls,
the Solenoid, Power and Relays for the Lift.
Select a Location
When selecting the location for your Lift, consider:
•
Architectural plans
. Consult the architectural plans for your desired installation location. Verify
no conflicts exist between what you want to do and what the architectural plans detail.
•
Available space
. Verify there is enough space for the Lift: front, back, sides, and above. Refer to
below and
•
Overhead obstructions
. Check for overhead obstructions such as building supports, heaters,
electrical lines, low ceilings, hanging lights, and so on.
You do not want your Vehicles
hitting obstructions
.
•
Power
. You need access to a 220 VAC single phase power source for the Power Unit.
•
Outdoor installations
. PL-6000DC Lifts are
not
designed to be installed outdoors.
Outdoor
installation is prohibited
.
•
Shimming
. If your Concrete floor is not level, you can use Shims under the bases of the Posts, to
level the Lift. To estimate your Shim requirements, use a transit level and targets to check for
flatness. Use the Shims if necessary.
Important
:
Do not shim a Post more than half an inch.
•
Floor
. Only install the Lift on a level, concrete floor; do not install on asphalt or any other surface.
The Concrete floor where you install your Lift must meet the following requirements:
150 mm / 6” thick with a compressive strength of 4,350 psi and cured for a minimum of 28
Days.
The Pre-Existing Concrete Floor
must
be test drilled to determine the actual thickness of the
Concrete at the location you wish to install the lift.
The floor must be a flat, and level;
do not install the Lift on a surface with a slope of
more than 1% (0.57°)
.
Summary of Contents for PL-6000DC
Page 12: ...PL 6000DC Two Post Parking Lift 12 P N 5900273 Rev A1 May 2022 Typical Height Requirements ...
Page 20: ...PL 6000DC Two Post Parking Lift 20 P N 5900273 Rev A1 May 2022 Drawing not to scale ...
Page 31: ...PL 6000DC Two Post Parking Lift 31 P N 5900273 Rev A1 May 2022 Drawing not to scale ...
Page 70: ...PL 6000DC Two Post Parking Lift 70 P N 5900273 Rev A1 May 2022 Drawing not to scale ...
Page 73: ...PL 6000DC Two Post Parking Lift 73 P N 5900273 Rev A1 May 2022 Labels ...
Page 74: ...PL 6000DC Two Post Parking Lift 74 P N 5900273 Rev A1 May 2022 ...
Page 75: ...PL 6000DC Two Post Parking Lift 75 P N 5900273 Rev A1 May 2022 ...
Page 80: ...PL 6000DC Two Post Parking Lift 80 P N 5900273 Rev A1 May 2022 ...
Page 84: ...PL 6000DC Two Post Parking Lift 84 P N 5900273 Rev A1 May 2022 Maintenance Log ...
Page 85: ...PL 6000DC Two Post Parking Lift 85 P N 5900273 Rev A1 May 2022 Maintenance Log ...
Page 86: ...PL 6000DC Two Post Parking Lift 86 P N 5900273 Rev A1 May 2022 Maintenance Log ...
Page 87: ...PL 6000DC Two Post Parking Lift 87 P N 5900273 Rev A1 May 2022 Maintenance Log ...