26
STEP 7
(Power Unit Electrical Connection)
1. Have a certified electrician run the power supply to
motor and wire solenoids (where appropriate) and the
Control Panel. Refer to the data plate found on the motor
for proper power supply and wire size. SEE WIRING
INSTRUCTIONS AFFIXED TO MOTOR FOR PROPER
WIRING INSTRUCTIONS.
2. After Control Panel electrical connection the panel may
be secured to the Front Post with the supplied button head
screws. (See Fig 7.1)
STEP 8
(Hydraulic Fittings)
For a Multiple Unit installation -
1. Locate the hydraulic fittings and solenoid valves.
2. Connect the Hydraulic Hose, 90° ORB x JIC fitting,
straight ORB reducing fitting and the power unit solenoid
valve to the ports in the Power Unit.
DO NOT USE TEFLON
TAPE on the JIC flared end.
(See Fig 8.1)
DANGER!
DO NOT PERFORM ANY MAINTENANCE OR
INSTALLATION OF ANY COMPONENTS WITHOU
T FIRST ENSURING THAT ELECTRICAL POWER HAS
BEEN DISCONNECTED AT THE SOURCE OR PANEL
AND CANNOT BE RE-ENERGIZED UNTIL ALL
MAINTENANCE AND/OR INSTALLATION
PROCEDURES ARE COMPLETED.
DANGER !
ALL WIRING MUST BE PERFORMED
BY A LICENSED ELECTRICIAN.
DANGER!
RISK OF EXPLOSION! THIS EQUIPMENT HAS INTERNAL
ARCING OR PARTS THAT MAY SPARK AND SHOULD
NOT BE EXPOSED TO FLAMMABLE VAPORS. MOTOR
SHOULD NOT BE LOCATED IN A RECESSED AREA OR
BELOW FLOOR LEVEL. NEVER EXPOSE MOTOR TO
RAIN OR OTHER DAMP ENVIRONMENTS. DAMAGE TO
MOTOR CAUSED BY WATER IS NOT COVERED UNDER
WARRANTY.
WARNING!
DO NOT RUN POWER UNIT WITHOUT OIL. DAMAGE TO
POWER UNIT PUMP CAN OCCUR. THE POWER UNIT MUST
BE KEPT DRY. DAMAGE TO POWER UNIT CAUSED BY
WATER OR OTHER LIQUIDS SUCH AS DETERGENTS, ACID
ETC., IS NOT COVERED UNDER WARRANTY.
OPERATE LIFT ONLY BETWEEN TEMPERATURES OF
41 °- 104° F. IMPROPER ELECTRICAL HOOK-UP CAN
DAMAGE MOTOR AND WILL NOT BE COVERED UNDER
WARRANTY. MOTOR CAN NOT RUN ON 50HZ WITHOUT A
PHYSICAL CHANGE IN THE MOTOR.
USE A SEPARATE CIRCUIT BREAKER FOR EACH POWER
UNIT. PROTECT EACH CIRCUIT WITH TIME DELAY FUSE
OR CIRCUIT BREAKER.
FOR 208-230 VOLT, SINGLE PHASE, USE A 25 AMP FUSE.
FOR 208-230 VOLT, THREE PHASE, USE A 20 AMP FUSE.
FOR 380-440 VOLT, THREE PHASE, USE A 15 AMP FUSE.
Fig 7.1
Fig 8.1
M4 Button
Screws
Power
Unit
Solenoid
Valve
Straight ORB
reducing fitting
90° ORB x
JIC fitting