24
IMPORTANT POWER-UNIT
INSTALLATION NOTES
n
DO NOT run power unit without oil. Damage to pump can occur.
n
The power unit must be kept dry. Damage to power unit caused by water or other liquids such as
detergents, acid etc., is not covered under warranty.
n
Improper electrical connection can damage motor and will not be covered under warranty.
n
Motor can not run on 50HZ without a physical change in the motor.
n
Use a separate breaker for each power unit.
n
Protect each circuit with time delay fuse or circuit breaker.
n
For 208-230 volt, single phase, use a 25 amp fuse.
n
For 208-230 volt, three phase, use a 20 amp fuse.
n
For 380-440 volt, three phase, use a 15 amp fuse.
Installation and adjustment.
DO NOT attempt to raise vehicle until a thorough operation check has been completed.
All wiring must be performed by a certified electrician only.
DANGER!
DO NOT PERFORM ANY MAINTENANCE OR INSTALLATION
OF ANY COMPONENTS WITH OUT FIRST ENSURING THAT
ELECTRICAL POWER HAS BEEN DISCONNECTED AT THE
SOURCE OR PANEL AND CANNOT BE RE-ENERGIZED UNTIL
ALL MAINTENANCE AND/OR INSTALLATION PROCEDURES
ARE COMPLETED.
SEE WIRING INSTRUCTIONS AFFIXED TO
MOTOR FOR PROPER WIRING INSTRUCTIONS.