![BENDIX XVision Manual Download Page 16](http://html1.mh-extra.com/html/bendix/xvision/xvision_manual_2731885016.webp)
16
DISPLAY
Maintaining the Combiner Mirror
The combiner is a sensitive optical element and should be
cleaned when it becomes dirty or filled with debris. Dirt and
debris can affect the display performance.
1. Remove heavy dirt or grit with air.
2. Clean the combiner with a soft, damp cloth moistened
with window cleaning solution. Shop rags and paper
towels will scratch this optical surface.
NOTE:
Do not use ammonia to clean any of the
display components. It will remove scratch-resistant
and anti-glare coatings.
Replacing the Combiner Mirror
1. Locate the depression in the center of the combiner door.
Refer to Figure 28.
FIGURE 29 - REPLACEMENT FOLD MIRROR
2. Pry the old fold mirror out by inserting a small
screwdriver or pocket knife into one of the depressions
and pushing upward.
3. Snap the new fold mirror gently into place.
2. Pry the old combiner out by inserting a small
screwdriver or pocket knife into the depressions and
pushing upward.
3. Snap the new combiner gently in place.
Maintaining the Fold Mirror
Remove heavy dirt or grit from the fold mirror with air. Clean
the fold mirror with a soft, damp cloth moistened with window
cleaning solution. Shop rags and paper towels will scratch
this optical surface.
NOTE:
Do not use ammonia to clean any of the display
components. It will remove scratch-resistant and
anti-glare coatings.
Replacing the Fold Mirror
1. Locate one of the four depressions along the perimeter
of the fold mirror. Refer to Figure 29.
Depressions
in Fold Mirror
FIGURE 28 - REPLACEMENT COMBINER
Depression in
Combiner Door
Combiner
Mirror