2.4 When this appliance is first used it is important to note that you will experience
some fumes and smells in the room of operaon. Any fumes emiLed during the
first few minutes of use can be quite pungent and it is advised that a window is
opened unl this subsides. Smells associated with paints, oils and starch from
ceramic components may last several hours but will rapidly diminish over the first
few uses of the appliance.
It is advisable that the appliance is always run on high for a period of at least 20
minutes before turning to low, to ensure opmal flue performance and to reduce
the possibility of soong.
It should be noted that as with all flame effect gas appliances, some soong can be
evident and can be cleaned away—see cleaning instrucons on previous pages.
The following table should be used to idenfy any problems experienced with the
operang or running of your appliance prior to contacng the manufacturer or
retailer regarding service.
Running in
Trouble shoong
warranty
The Be Modern 5 year limited guarantee is managed directly by Be Modern Ltd.
With our experienced Gas Safe engineers and through our extensive network of
service centres throughout the UK we will ensure your appliance receives the right
care should anything fail prematurely.
Can you hear a connuous clicking during the
ignion process?
YES
NO
Check BaLery
Does the pilot light?
YES
NO
Check and remove soot or
ember
wire
near the pilot
Does the pilot go out when the lever is
released?
YES
Try again, but before releasing
the lever give a firm push to the
le before releasing the lever.
Does the fire light and run ok then
subsequently turns off automacally
YES
The pilot aeraon may have
become blocked refer to page 8
Does the flame picture look wrong?
YES
Check log placement as per the
user instrucons see pages 9-12
Does the glass have grey water marks on
inside surface
YES
The glass will require infrequent
cleaning dependant on use. See
page 6 to open door.
Do you see marks or discolouraon above the
centre of the appliance?
YES
The gas fire is spilling, turn the
unit off and call for your gas safe
engineer.
THE FIRE WILL NOT LIGHT
THE FIRE GOES OUT
VISUAL PROBLEMS