38
4.6 Combus>ble Shelf
This appliance may be fiLed below a surround with a
combus>ble
shelf providing the
following dimensional criteria is met:
There must be a minimum distance of 250mm from the top of the appliance to the underside
of the shelf.
The shelf must not project more than 150mm from the mounng surface of the appliance into
the room. If the shelf projects more than 150mm then the distance between the top of the
appliance and the underside of the shelf must be increased accordingly; for every 10mm of
projecon above 150mm the distance between the fire and shelf must be increased by 25mm
Shelf Protrusion (X)
Min. Distance (Y) Between Fire and Shelf
150mm
250mm
160mm
275mm
170mm
300mm
180mm
325mm
190mm
350mm
200mm
375mm
Any combusble side wall, for example leg of mber mantel, should be a minimum of 200mm
from the appliance.
INSTALLATION
INSTRUCTIONS
COMBUSTIBLE
SHELF