INSTALLATION
INSTRUCTIONS
Back Panels
3.4.5
If the appliance is being fiLed with the flange against slips or a back panel, it
must be of a suitable material. The back-panel must be able to withstand 150
o
C
connuously or be ‘O’ rated (fire retardant). It is recommended that this back panel
is constructed of 4 secons then re-bonded as a single panel to provide the correct
opening size and make the installaon easier. Single piece back-panels or backing
slips are highly likely to crack in me and no responsibility will be held by the
appliance manufacturer for such installaons.
Debris
3.4.6
A clearance of at least 32mm is required behind the appliance to ensure
adequate debris collecon volume is aLained and provide to clearance when
venng from the rear exit. When connected to the 5” liner or to 5” flue pipe this is
not required.
Venlaon
3.5
No purpose made venlaon is required for this product as the nominal input
does not exceed 7.0 kW, however if spillage is detected during the installaon
commissioning it may be necessary to provide some addional venlaon. Always
check the current rules in force for the country of installaon.
Gas Supply
3.6
This appliance is suitable for use on natural gas (G20) only from a governed
meter. It is the responsibility of the installer to ensure that correct pipe sizing has
been supplied to the site for correct performance. 8mm diameter ducle copper
tubing should be used for the run to the appliance at a maximum length of 500mm
to avoid pressure drops. The appliance is supplied with a restricon device which
must be used as part of the installaon. There should be no soldered joints within
the firebox of the appliance.
3.4.4
The following diagram shows the area within the wall of installaon which
must be clear of all combusble materials.
Combusbles