Service & Maintenance
GB
Maintenance
The Belle Group ‘PCLX’ range is designed to give many years of trouble free operation. It is recommended that an approved Belle
Group dealer carries out all major maintenance and repairs. Always use genuine Belle Group replacement parts, the use of spurious
parts may void your warranty.
Before any maintenance is carried out on the machine, switch off the engine and disconnect the HT lead from the sparkplug.
Always set the ‘PCLX’ on level ground to ensure any ô uid levels will be correctly read. Only use recommended oils (see chart on follow-
ing page).
Running In Period
When the ‘PCLX’ is â rst used from new, the engine oil must be changed after the initial running in period (see engine manual for full de-
tail). The vibrator shaft case oil must be replaced after the â rst 100 hours use, then after every 500 working hours. For detail on vibrator
shaft case oil replacement, see ‘Vibrator unit’.
The belt tension should be checked after 4 hours use.
Routine Maintenance
After First First month / 3 Months
6 months
4 hours
20Hours
50 Hours
100 Hours
Engine Oil
Check Level
9
Change
9
9
Air Filter
Check Condition
9
9
Clean / Replace
9
Spark Plug
Check / Clean
9
Drive Belt
Tension
9
9
9
Oil / Fuel Type & Quantity - Spark Plug Type
Oil type
Quantity
Fuel Type
Capacity
Spark Plug
Electrode
(Litre)
(Litre)
Type
Gap
(mm)
Petrol Honda GX100
S.A.E. 10W 30
0.4
Unleaded
1.2
BM4a or
0.6 - 0.7
BmR4a
Vibrator
Turbine Oil 32
0.22
N/A
N/A
N/A
N/A
Vibrator
Unit.
Remove the plug complete with seal, check that the oil level reaches the bottom thread on the oil
plug hole. Top up as necessary with the correct oil (see chart).