POWER SUPPLY -
2 smart
(PS2.VDN.ENW)
INPUT
: ~230V ± 10% / 50 Hz
/ 0,4 A
OUTPUT
: 28V ± 10%
/ 1,2 A
RISK OF
ELECTRICAL SHOCK!
CAUTION! DO NOT REMOVE
THE SAFETY LID!
CAUTION! DO NOT REMOVE
THE SAFETY LID!
Check the precision of the connections in the system!
COMMISIONING OF THE SYSTEM
6.2 The checking of connections in the system and the connection of
the power supply unit
6.1 Description of the Power supply unit
The
Power supply unit
includes:
Protection lid for
connections
Front lid
LED -
GREEN signaling
= presence of tension
Connect the Power supply unit to the 230 V
AC
network, by connecting the two automatic 10A
fuses, installed on phase and null.
Protection lid
for connections
10/16
5
.3
Con
nection of the auxiliary command
(opt
ional
)
Direct current (DC)
Alternative current (AC)
Outdoor panel
JP
Auxiliary automation
- direct current (DC)
Cable 2 x 0.75 mm²
JP1
~
Cable
2 x 0.75 mm²
Outdoor panel
Transformer
~
Auxiliary
automation
-alternative current (AC)
P
A
/
Y
2
A
1
BUT
Y
1
L
2
L
1
JP
JP1
Note:
After the correct installation of the electromagnetic lock and/or of the auxiliary automation, the
Unlock Parameter
must be
set on one terminal
(
See
S
6
. Unlock parameter settings
)
.
The parameter will be saved in the Outdoor panel automatically, so you
need to set only one terminal. ( in case there is another terminal connected in parallel).
Ÿ
JP1 not connected :
The outdoor panel
can
switch
a maximum current of 1A
AC
for
the auxiliary automation.
Ÿ
JP1 connected
: The outdoor panel can
supply the auxiliary automation with
maximum 0.25A.
Ÿ
JP1 not connected:
The auxiliary
automation is supplied from an external DC
source (see adjoining diagram). The outdoor
panel can switch a current of maximum
1
A
for the supply of the auxiliary automation.
Ÿ
The lock actuating button (push button -
normal open) from the interior of the
building will be connected to the BUT and
A1 terminals of the outdoor panel.
D
C
D
C
1
2
12 V
AC
230 V
AC
6
P
A
1
BUT
Y
1
L
2
L
1
A
2
/
Y
2