è
ATTENTION! The installation, the connection to the 230V/50 Hz network and
the maintenance of the Power supply unit will only be carried out by
authorized personnel!
è
The installation of the Power supply unit is recommended to be made within
an electrical panel.
è
ATTENTION! DO NOT REMOVE THE FRONT LID! DANGER OF ELECTRIC SHOCK!
Only the protection lids of the connections can be removed.
è
ATTENTION! It is mandatory for the supply of the Power supply unit from the
230 V/50Hz network to be made through two automatic fuses of 10 A (on
phase and null). The connection of the F and N terminals of the Power supply
unit will be made through two isolated (Cu) wires, with a section of 0,75mm²
è
ATTENTION! During the installation, connection of the Power supply unit at
the 230 V/50Hz network and during service, the safety fuses from the
electrical panel must be opened. (POWER OFF)
è
The connection of the grounding copper wire (0,75mm²) between the
grounding hub of the electrical panel and the grounding terminal of the
Power supply unit is MANDATORY.
05/16
INSTALLATION
4.1 Recommended cables
Outdoor panel Power supply unit
Using different cables between the
Outdoor panel
and the
Power supply unit
, the following
distances can be reached:
- Pair Cable (parallel) 2 x 0.75 mm² for distances up to 50 m;
- Twisted Cable 2 x 0.75 mm² for distances up to 60 m;
- Twisted Cable 2 x 1 mm² for distances up to 80 m;
For distances greater than 80 m, please request additional information from the producer.
Video Terminal
Outdoor panel
Pair Cable (parallel) (Cu) 2 x 0,75 mm² for distances of maximum 50 m or
pair cable (Cu) 2 x 1 mm² for distances of maximum 120 m.
Electromagnetic lock (optional)
Power supply unit
Flexible, copper multi-wire cable 3 x 0,75 mm²
230 V
AC
network
4.2 Safety instructions for installation
Power supply unit
Using different cables between the
Power supply unit
and the
Terminal
, the following
distances can be reached:
- Pair Cable (parallel) 2 x 0.75 mm² for distances up to 30 m;
- Twisted Cable 2 x 0.75 mm² for distances up to 50 m;
- Twisted Cable 2 x 1 mm² for distances up to 60 m;
For distances greater than 80 m, please request additional information from the producer.
EN
4