Configuration
4.16 USB Port
4.16 USB Port
You can use a USB to RS232 converter to send data out of the serial port from the Ethernet
network in the same manner as the RS232 expansion port function. To specify the values for
the USB port parameters, click
USB Port
in the
Configuration
section of the main menu. The
following tables describe the parameters available in the configuration form. IPv6 TCP/UDP
client/server is supported as well.
Item
Description
Baudrate
Applied communication speed.
Data Bits
Number of data bits.
Parity
Control parity bit:
•
none
– data will be sent without parity.
•
even
– data will be sent with even parity.
•
odd
– data will be sent with odd parity.
Stop Bits
Number of stop bit.
Split Timeout
Time to rupture reports. If the gap between two characters exceeds
the parameter in milliseconds, any buffered characters will be sent
over the Ethernet port.
Protocol
Communication protocol:
•
TCP
– communication using a linked protocol TCP.
•
UDP
– communication using a unlinked protocol UDP.
Mode
Mode of connection:
•
TCP server
– The router will listen for incoming TCP connection
requests.
•
TCP client
– The router will connect to a TCP server on the
specified IP address and TCP port.
Server Address
When set to
TCP client
above, it is necessary to enter the
Server ad-
dress
and
TCP port
. IPv4 and IPv6 addresses are allowed.
TCP Port
TCP/UDP port used for communications. The router uses the value
for both the server and client modes.
Inactivity Timeout
Time period after which the TCP/UDP connection is interrupted in
case of inactivity.
Table 63: USB Port Configuration 1