Install MAMMUTHUS switch
Issued in December, 2020
2.5
Operate the device
Operate in the following steps:
Fix the connector on the device by the screws.
You may check the tightening torque stipulated in "General Technical
Data" on Page 50.
Enable the power voltage.
2.6
Connecting the data cable
In the environment with high electrical interference, notice the following
general suggestions related to the data cable connection:
Shorten the length of the data cable as much as possible.
Use optical fiber data cable for data transmission between the buildings.
When using the copper cable, fully separate the power cable from the
data cable.
Preferably, install it in separate cable channel.
Ensure that the power cable and data cable will not be arranged in
parallel for long distance, preferably install them in different cable
channels.
If it is required to reduce the inductive coupling, it is required
to ensure that the power cable and data cable are crossed
at
90°.
Use the SF/UTP cable conforming to the requirements of ISO/IEC
11801:2002.
Connect the data cable according to your need.
For more information,
consult "Device Name and Product Code" on Page
21.
2.7
Fill in the label
The MAC address information on the front of the device can help you to
identify such device.
Summary of Contents for HIRSCHMANN IT MAMMUTHUS MTM8000 Series
Page 18: ...18 Install MAMMUTHUS switch Issued in December 2020 MTM8000 16X4Q S MTM8000 16X S...
Page 53: ...53 Install MAMMUTHUS switch Issued in December 2020 7 2 Dimensional Drawing Basic devices...
Page 54: ...54 Install MAMMUTHUS switch Issued in December 2020 Power module Engine module...
Page 55: ...55 Install MAMMUTHUS switch Issued in December 2020 Fan module...
Page 65: ...Install MAMMUTHUS switch Issued in December 2020 65...