Installation and operating manual
EN
48 METPOINT
®
BDL compact
Home
Settings
Sensor settings
A1
Confirm the changes with
OK
. The sensor
configuration is now completed.
For other sensor configuration options, see chapters
See also chapter 11.2.2.7
Labelling and configuring text fields
Note:
After confirming with
OK
, the field labels change to black. The values and settings are applied.
Caution:
Reference temperature and reference pressure (factory settings 20°C, 1000 hPa):
All volume flow (m³/h) and consumption (m³) values shown on the display refer to 20 °C and 1000 hPa (according to
ISO 1217). Alternatively, enter 0°C and 1013 hPa (=standard cubic metre according to DIN 1343) as the reference values. Do
not enter the operating pressure or the operating temperature as the reference values!
11.2.2.2.
Labelling measurements and defining resolution (decimals)
Note:
To configure the
Resolution
(decimal places), the
Short name
and the
Value name
, click the
Tool
button!
Tool button:
Home
Settings
Sensor-settings
A1
Tool button
For the
Value
to be recorded, enter a
Name
with
max. 10 characters. This name is then used in the
Charts
and
Chart/current values
menus.
Otherwise, the default designation (e.g.
A1a
) is
displayed.
A1
indicates the channel;
a
is the first value in the
channel,
b
would be the second, and
c
the third.
To adjust the
Resolution
of the decimal places, touch
the arrow buttons (0 to 5 decimals places).
See also chapter 11.2.2.7
Labelling and configuring text fields