Technical description
DRYPOINT RA 200 – 2500 NA
23
5.17. Electronic level controlled condensate drain BEKOMAT
The electronic level controlled drain BEKOMAT has a special condensate management that makes sure that
condensate is drained safely without any unnecessary air-loss. This drain consists of a condensate accumulator where
a capacitive sensor continuously checking liquid level is placed: as soon as the accumulator is filled, the sensor passes
a signal to the electronic control and a diaphragm solenoid valve will open to discharge the condensate. Right in time
the discharge line will be closed again without wasting compressed air.
ATTENTION!
These BEKOMAT condensate drains have been specially designed for the use in a refrigerant dryer DRYPOINT RA
NA. Any Installation in other compressed air treatment units or the exchange against a different drain brand may lead
to malfunction.Do not exceed the max. operating pressure (see type plate)!
Make sure when the dryer starts the upstream valve is open.
NOTE:
For detailed information on drainer functions, troubleshooting, service and replacement parts, please refer to
the BEKOMAT drainer manual.