Safety rules
6
DRYPOINT RA 200 – 2500 NA
1.2.
Warnings
DANGER!
Compressed air!
Compressed air is a highly hazardous energy source.
Never work on the dryer with pressure in the system.
Never point the compressed air or the condensate drain outlet hoses towards anybody.
The user is responsible for the proper installation of the dryer. Failure to follow instructions given in the
“Installation” chapter will void the warranty. Improper installation can create dangerous situations for personnel
and/or damages to the machine could occur.
DANGER!
Mains voltage!
Only qualified personnel are authorized to service electrically powered devices. Before attempting
maintenance, the following conditions must be satisfied:
Ensure that main power is off, machine is locked out, tagged for service and power cannot be restored during
service operations.
Ensure that valves are shut and the air circuit is at atmospheric pressure. De-pressurize the dryer.
CAUTION!
Refrigerant!
These refrigerating air dryers contain R134a or R404A HFC type refrigerant fluid. Refer to the specific
paragraph - maintenance operation on the refrigerating circuit.
WARNING!
Unauthorized interference!
Warranty does not apply to any unit damaged by accident, modification, misuse, negligence or misapplication.
Unauthorized alterations will immediately void the warranty.
In case of fire, use an approved fire extinguisher, water is not an acceptable means in cases of electrical fire.
1.3.
Proper Use of the Dryer
This dryer has been designed, manufactured and tested for the purpose of separating the humidity normally contained
in compressed air. Any other use has to be considered improper.
The Manufacturer will not be responsible for any problem arising from improper use; the user will bear responsibility for
any resulting damage.
Moreover, the correct use requires the adherence to the installation instructions, specifically:
•
Voltage and frequency of the main power.
•
Pressure, temperature and flow-rate of the inlet air.
•
Pressure, temperature and cooling water capacity (Water-Cooled).
•
Ambient temperature.
This dryer is supplied tested and fully assembled. The only operation left to the user is the connection to the plant in
compliance with the instructions given in the following chapters.
WARNING!
Improper use!
The purpose of the machine is the separation of water and eventual oil particles present in compressed air.
The dried air cannot be used for breathing purposes or for operations leading to direct contact with foodstuff.
This dryer is not suitable for the treatment of dirty air or of air containing solid particles.
Summary of Contents for DRYPOINT RA 1000/AC NA
Page 37: ...List of attachments DRYPOINT RA 200 2500 NA 37 7 2 2 Exploded view DRYPOINT RA 200 350 NA ...
Page 38: ...List of attachments 38 DRYPOINT RA 200 2500 NA 7 2 3 Exploded view DRYPOINT RA 400 500 NA ...
Page 39: ...List of attachments DRYPOINT RA 200 2500 NA 39 7 2 4 Exploded view DRYPOINT RA 600 1250 NA ...
Page 40: ...List of attachments 40 DRYPOINT RA 200 2500 NA 7 2 5 Exploded view DRYPOINT RA1500 2500 NA ...
Page 51: ...List of attachments DRYPOINT RA 200 2500 NA 51 ...