The direction of flow for the separator must be observed during installation. This must match the direction of flow for
the pipeline.
Direction of flow left » right (factory default)
Direction of flow
Right
»
left
1
2
3
2
1
3
The housing head and housing body use a double trapezoidal thread. The direction of flow through the separator can be
adjusted to that of the pipeline by turning the housing head 180°. The direction of flow is indicated via arrows
[2]
and
a raised marking
[3]
on the housing head. This must be aligned as shown. The safety runner
[1]
must always be easily
accessible on the front side.
For maintenance and repair work, it is recommended to install a bypass line
[4]
and shut-off valve
[5]
.
4
5
1. Attach sealing material, e.g. PTFE band (EN 837-2) to the pipe ends
2. Screw pipe thread into the separator inlet until the connection is solid and sealed
3. Screw pipe thread into the separator outlet until the connection is solid and sealed
After completing assembly work, check to ensure the housing body is screwed in correctly, the safety runner is pushed
up and the locking screw is hand-tightened. Complete a leak test to check installation work. For more information, see
CLEARPOINT
®
Water separator
Installation and operation instructions
28 | 56
Summary of Contents for CLEARPOINT M010
Page 49: ...Installation and operation instructions CLEARPOINT Water separator 49 56 ...
Page 50: ...CLEARPOINT Water separator Installation and operation instructions 50 56 ...
Page 52: ...CLEARPOINT Water separator Installation and operation instructions 52 56 ...
Page 54: ...CLEARPOINT Water separator Installation and operation instructions 54 56 ...