5. Technical data
5.1 Separator performance data
CLEARPOINT
®
S040
S050
S075
M010
M015
Connection ['']
3/8
1/2
3/4
1
1 1/2
Volume flow rate at 7bar(g)
(101.53 psi(g))
energy-optimized
[m³/h]([cfm])
*1
46
(27.08)
130
(76.52)
195
(114.77)
325
(191.29)
545
(320.76)
Differential pressure [mbar] ([psi])
saturated
Ø
60
(0.878)
Category according to PED
2014/68/EU
-
-
-
-
-
Min./max. operating
pressure[bar(g)] ([psi(g)])
1,5 ... 16
(21.76 ... 232)
Min./max. Operating temperature
[°C] ([F°])
+2 ... +60
(+35.6 ... +140)
Load test in accordance with
AD2000
10000 load changes
≙
pressure differential ≥3.2 bar (46.41 psi)
at 16 bar(g) (232 psi(g))
Medium
Compressed gases in fluid group 2 in accordance with PED 2014/68/EU, free
from aggressive and corrosive components
Weight [kg] ([lbs])
0.75
(1.65)
0.85
(1.87)
1.7
(2.36)
2.1
(4.63)
4.1
(9.04)
Volume [l] ([gal(US)])
0.25
(0.066)
0.31
(0.082)
0.87
(0.23)
1.12
(0.30)
2.52
(0.67)
*1 Volume flow rate at 7 bar(g)(101.53 psi(g)) based on +20 °C (+68 °F) and 1 bar (abs) (14.5 psi)
Installation and operation instructions
CLEARPOINT
®
Water separator
21 | 56
Summary of Contents for CLEARPOINT M010
Page 49: ...Installation and operation instructions CLEARPOINT Water separator 49 56 ...
Page 50: ...CLEARPOINT Water separator Installation and operation instructions 50 56 ...
Page 52: ...CLEARPOINT Water separator Installation and operation instructions 52 56 ...
Page 54: ...CLEARPOINT Water separator Installation and operation instructions 54 56 ...