background image

HEAVY DUTY

AIR FILTRATION

SYSTEM

Your new tool has been engineered and manufactured to WEN’s highest standards for dependability, 

ease of  operation, and operator safety. When properly cared for, this product will supply you years 

of  rugged, trouble-free performance. Pay close attention to the rules for safe operation, warnings, 

and cautions. If  you use your tool properly and for intended purpose, you will enjoy years of  safe, 

reliable service.

IMPORTANT:

NEED HELP? CONTACT US!

Have product questions? Need technical support? 

Please feel free to contact us at:

800-232-1195

[email protected]

WENPRODUCTS.COM

(M-F 8AM-5PM CST)

bit.ly/wenvideo

For replacement filters visit

WENPRODUCTS.COM

184841

CSA MODEL TA25

NOTICE: Please refer to wenproducts.com for the most up-to-date instruction manual.

Summary of Contents for 3415

Page 1: ...safe operation warnings and cautions If you use your tool properly and for intended purpose you will enjoy years of safe reliable service IMPORTANT NEED HELP CONTACT US Have product questions Need technical support Please feel free to contact us at 800 232 1195 techsupport wenproducts com WENPRODUCTS COM M F 8AM 5PM CST bit ly wenvideo For replacement filters visit WENPRODUCTS COM 184841 CSA MODEL...

Page 2: ...ed Dimensions 3415 3415T 110 120 V 60 Hz 3A 1044 CFM High Speed 702 CFM Medium Speed 556 CFM Low Speed 5 Micron Outer Air Filter Model 3415AF5 1 Micron Inner Air Filter Model 3415AF1 63 68 dB 26 feet 55 pounds 30 3 x 24 x 12 2 in 770 x 610 x 310 mm 2 Specific Safety Rules For Air Filtration Systems Know Your Air Filtration System Assembly and Adjustments Operation Unpacking Exploded View Parts Lis...

Page 3: ...ng gloves neckties or jewelry rings watches etc when op erating the tool Inappropriate clothing and items can get caught in moving parts and draw you in ALWAYS wear non slip footwear and tie back long hair 8 WEAR A FACE MASK OR DUST MASK to fight the dust produced by sawing operations WARNING Dust generated from certain materials can be hazardous to your health Always oper ate the tool in a well v...

Page 4: ...ore servicing or changing filters 2 If mounting the air filtration system to the ceiling Make sure the bottom of the air filtration system is at least 7 feet above the floor level Anchor the air filtration system only to building structures capable of holding at least 100 lbs Do not anchor the filtration system to non structural components such as drywall false ceiling panels etc 3 Position the ai...

Page 5: ...elow shows the correct size to be used according to cord length and nameplate ampere rating When in doubt use a heavier cord The smaller the gauge number the heavier the cord Make sure your extension cord is properly wired and in good condition Always replace a damaged extension cord or have it repaired by a qualified person before using it Protect your extension cords from sharp objects excessive...

Page 6: ...arton or any packaging until the air filtration system is completely assembled If any part is dam aged or missing please contact our customer service at 800 232 1195 M F 8 5 CST 1 3 2 4 5 6 7 8 9 1 2 3 4 5 6 Mounting Hangers Mounting Brackets Control Panel Receiver Overload Protector Reset Button Power Cord Remote Control Air Filtration System with Inner and Outer Filters Installed Mounting Hanger...

Page 7: ...r false ceiling grids The unit must be situated at least 7 feet above the floor and at least 3 feet 1 m away from any heating cooling or air circulation vents 1 Install the wood screw hooks Fig 2 1 into the building sup port structure NOTE Wood screw hooks and chains used for ceiling mounting are not included Make sure to use chain and hooks that are properly rated for hanging this unit 2 Place a ...

Page 8: ...stem will operate before shutting itself off automatically The timer can only be set using the remote control 1 Press the TIMER button Fig 5 4 on the remote control to start the timer The cycle is 1 hour 2 hours 4 hours and clear the timer 2 The LED lights Fig 4 4 on the control panel will indicate the amount of time selected The unit will shut off automatically after the selected time interval el...

Page 9: ...ir filter cabinet Remove the outer filter Fig 6 2 from the cabinet housing 2 Carefully pull the inner filter Fig 7 2 out of the cabi net 3 Install a new inner filter Model 3415AF1 into the cabi net and install a new outer filter Model 3415AF5 on the back of the machine in the configuration as shown in Fig 8 4 Close the upper and lower lock clips to secure the outer filter in place REPLACING THE RE...

Page 10: ...EXPLODED VIEW PARTS LIST 10 1 3 53 54 5 6 7 4 19 17 16 15 14 13 47 21 30 26 25 24 43 37 35 33 40 39 45 44 27 12 11 10 2 28 2 20 18 46 34 38 36 41 42 22 8 23 9 51 52 29 55 56 57 58 50 1 31 ...

Page 11: ...ilter 5 Micron 1 25 3415 025 Handle 2 26 3415 026 Rubber Foot 4 27 3415 027 Flat Washer 6mm 6 28 3415 028 Rivet Nut M10X21 4 No Part No Description Qty 29 3415 029 Mount And Bolt Bag 1 30 3415 030 Housing 1 31 3415 031 Eye Bolt M10X20 4 33 3415 033 PC Wiring Harness 1 34 3415 034 Phillip s Head Screw M4 0 7X16 3 35 3415 035 Lock Washer 4mm 5 36 3415 036 Flat Washer 4mm 5 37 3415 037 Hex Nut M4 0 7...

Page 12: ...t be prepaid by the purchaser The prod uct must be shipped in its original container or an equivalent properly packed to withstand the hazards of ship ment The product must be fully insured with a copy of the warranty card and or the proof of purchase enclosed There must also be a description of the problem in order to help our repairs department diagnose and fix the issue Repairs will be made and...