Electrical installation • Instalación eléctrica
Installation électrique • Instalação eléctrica
english
Measures:
Observe all the valid rules and regu-
lations for electrical installation !
The removed control unit does no lon-
ger have IP protection and must be pro-
tected from damp!
CAUTION!
Maintenance work must only
be carried out when the device is in a
de-energized state! Any work involving
electrical parts must only be performed
by suitably qualified and authorized per
-
sonnel.
Danger!
Mains voltage!
In the case of contact with uninsula-
ted parts carrying mains voltage the-
re is a risk of electric shock including
injury or death!
Note before wiring:
• Check type plate for permissible
mains voltage and ensure conformity!
• The installation must be carried out
according to the valid regulations.
• Assign terminals as indicated!
• Electrical power must be discon-
nected prior to installation!
• Remove screw (
) and lift off top cover (
)
• Unscrew cable fitting (
) (where appli-
cable), remove blanking plug and insert
cable (
4
) for power supply (
).
• Connect cable (
4
) to terminals (
5
).
Terminal assignment VAC
KL1:1 PE-mains connection
KL1:2 L- or N-mains connection
KL1:3 N- or L-mains connection
Terminal assignment: VDC
KL1:1 PE-connection
KL1.2 0V
KL1.3 +24 V
Note:
There is no metallic isolation
between terminals KL1.1 - KL1.3 and
housings or the condensate connec-
tions.
The 24 VDC voltage supplied must meet
the requirements for extra-low safety
voltages (for instance, EN 61556-2-6).
• Lay cable (
4
) as depicted.
Stranded cable ends must be secured
by means of a cable binder (
6
).
• Replace top cover (
) and tighten screw
(
).
• Fasten the threaded cable connection
(
) loosely.