BEKOMAT 31 stand alone
4
Maintenance • Mantenimiento • Entretien • Manutenção
6
4
0
8
9
5
7
1
3
2
4
8
9
9
5
6
7
english
Maintenance recommendations
Replace service unit (
5
) annually.
Danger!
Compressed air!
In the case of contact with quickly or
suddenly released compressed air or
in the case of bursting plant compo-
nents there is a risk of serious injury
or death.
Measures:
Depressurize the BEKOMAT unit!
Danger!
Mains voltage!
In the case of contact with uninsula-
ted parts carrying mains voltage the-
re is a risk of electric shock including
injury or death!
Measures:
De-energize the BEKOMAT unit!
Remove control unit (
) by pres-
sing latching hook (
).
Detach Bekomat from outlet (
).
Remove design shell (
4
) (where
applicable) using a screw driver
(
0
).
Remove service unit (
5
) from pipe
at inlet by undoing union nut
or
by undoing screws (
6
) at elbow
connector (
7
)
or
by undoing screws (
8
) at inter-
mediate adapter (
9
) which is then
detached from the service unit by
downward movement.
• Check if new service unit (
5
) matches
control unit (
)
- type designation and colour of
latching hook (
)
• Fit new service unit (
5
) in reverse
order.
4
2
1
3
7
6
5
Assembly:
„Control unit onto service unit“
see page 16
Summary of Contents for BEKOMAT 31