On products with an FM, the machine will take in water for 10 seconds. If it reaches
50 pulses within this period, step transition will be allowed.
Step transition is not allows during water level measurement.
Position to turn the knob to
4 for water level sensor details; 7 for FM details
Warnings to be displayed on the 7S:
Refer to the knob position and information table
Condition to pass to the next step:
After water is taken until the "Pdoor + 16.0 Hz", which is the target level, from the
Prewash Valve,
and "Flow Meter OK/NOK" is displayed for the Prewash Flow Meter, if "Start/Pause"
button is pressed, next step is started.
Timeout: If "Start/Pause" button is not pressed within 2*3 = 6 minutes, it goes into
"OFF" mode.
Switching to next step:
After "Flow meter OK/NOK" is displayed, if "Start/Pause" button is pressed.
NOTE: If "ON/OFF" button is pressed for 3 seconds, machine goes into "OFF" mode.
Step 11: Main Wash Valve, and Main Wash Valve Flow Meter Check
Description:
The Main Wash Valve is activated.
On products without an FM, the machine will take in water until the key is pressed.
On products with an FM, the machine will take in water for 10 seconds. If it reaches
50 pulses within this period, step transition will be allowed.
Step transition is not allows during water level measurement.
Position to turn the knob to
4 for water level sensor details; 7 for FM details
Warnings to be displayed on the 7S:
Refer to the knob position and information table
Condition to pass to the next step:
After water is taken until the "Pdoor", which is the target level, from the Main Wash
Valve
and "Flow Meter OK/NOK" is displayed for the Main Wash Flow Meter, if
"Start/Pause" button is pressed, next step is started.
Timeout: If "Start/Pause" button is not pressed within 2*3 = 6 minutes, it goes into
"OFF" mode.
Summary of Contents for Arcelik BLG15 C7S
Page 10: ...BLG15 C7S SERVICE MANUAL Sensitivity Public ...
Page 11: ...BLG15 C7S SERVICE MANUAL Sensitivity Public Picture 3 12 Cover unlocking arm ...
Page 48: ...BLG15 C7S SERVICE MANUAL Sensitivity Public Picture 6 56 Picture 6 57 Picture 6 58 ...
Page 53: ...BLG15 C7S SERVICE MANUAL Sensitivity Public Picture 6 67 Picture 6 68 Picture 6 69 ...