BLG15 C7S SERVICE MANUAL
Sensitivity: Public
2) If there is no NTC error, however there is an error at the Mains Voltage ADC
inputs, 140rpm is applied;
3) If there is no problem at both checks above, maximum speed spin (1550-1600rpm)
is applied.
Warnings to be displayed on the 7S:
Refer to the knob position and information table
Condition to pass to the next step:
If there is water level sensor error, "Water Level Sensor Error" will be shown for 3
seconds and the step of "Display of the Errors occurred in Test Mode" which is the
last step of "Test" mode is started.
If there is not "Water Level Sensor" error, amount of the water within the drum will be
checked:
1) Read water level is lower than "15.0 Hz" in terms of frequency (if water
level is 15Hz higher than Psafety), before this step is realised, pumping will be
applied until "Psafety" level is decreased below 15.0 Hz. When the desired level is
reached, this step is realised automatically.
If "start/pause" button is pressed on during level decreasing process, this button
press will be ignored.
2) If the level is appropriate at the first entry into this step (if water level is lower than
"15.0 Hz"), this step will be realized without pumping.
Psafety level is found in the variable file.
The level which is defined in this step is a level between the Psafety level and the
Pdoor level.
Timeout: If the "Start/Pause" button is not pressed within 2*3 minutes, it goes into
"OFF" mode.
Switching to next step:
"Start/Pause" button is pressed.
NOTE: If you turn the knob to Off position, the machine will switch to "OFF" mode.
Step 8: Drying module check Step 1
Description:
If it is the Drying function, the Drying module heater will run.
Warnings to be displayed on the 7S:
Refer to the knob position and information table
Condition to pass to the next step:
Summary of Contents for Arcelik BLG15 C7S
Page 10: ...BLG15 C7S SERVICE MANUAL Sensitivity Public ...
Page 11: ...BLG15 C7S SERVICE MANUAL Sensitivity Public Picture 3 12 Cover unlocking arm ...
Page 48: ...BLG15 C7S SERVICE MANUAL Sensitivity Public Picture 6 56 Picture 6 57 Picture 6 58 ...
Page 53: ...BLG15 C7S SERVICE MANUAL Sensitivity Public Picture 6 67 Picture 6 68 Picture 6 69 ...