BLG15 C7S SERVICE MANUAL
Sensitivity: Public
4 for water level sensor details; 7 for FM details
Warnings to be displayed on the 7S:
Refer to the knob position and information table.
Condition to pass to the next step:
a) If there is water level sensor error, "Water Level Sensor Error" will be shown for 3
seconds without water being taken in and the step of "Display of the Errors occurred
in Service Mode" which is the last step of "Service" mode is started.
b) If there is not Water Level Sensor Error, but there is NTC error; "NTC Error" is
displayed until water is taken in up to 'Psafety - 20.0 Hz' frequency level, heater will
not be activated and "Start/Pause" button needs to be pressed in order to pass to the
next step. Unless the water level is completed, next step will not be started even if
the "Start/Pause" button is pressed.
c) If none of the above errors is available (if everything is normal), after water intake
is completed and "Water Heater" is displayed in the text line, next step will be taken
in 2 ways:
i) If the "Start/Pause" button is pressed;
ii) When the temperature of the water rises above +5 C
after the water intake is completed and the heater is activated immediately.
Timeout: If "Start/Pause" button is not pressed within 2*3 = 6 minutes, it goes into
"OFF" mode.
Switching to next step:
Press the "Start/Pause" button.
(if there is not any error and water intake is completed)
NOTE: If you turn the knob to Off position, the machine will switch to "OFF" mode.
Step 16: Bluetooth Connection check
Description:
This step is not performed in service mode.
Condition to pass to the next step:
If the Bluetooth connection has been established as defined, this step will be passed
automatically.
If there has been a problem in the Bluetooth connection, the machine will not
proceed to the Pump step. Error code will be written
Switching to next step:
If the Bluetooth connection is OK, the machine will automatically switch to the next
step.
Summary of Contents for Arcelik BLG15 C7S
Page 10: ...BLG15 C7S SERVICE MANUAL Sensitivity Public ...
Page 11: ...BLG15 C7S SERVICE MANUAL Sensitivity Public Picture 3 12 Cover unlocking arm ...
Page 48: ...BLG15 C7S SERVICE MANUAL Sensitivity Public Picture 6 56 Picture 6 57 Picture 6 58 ...
Page 53: ...BLG15 C7S SERVICE MANUAL Sensitivity Public Picture 6 67 Picture 6 68 Picture 6 69 ...