Technical data
1.1 General
Pump
Delivery rate: ......................................................................................................................................................................... 120 cm³/min
Lubricant: ...................................................................... greases up to NLGI class 2 without solid contents (other lubricants on request)
Operating pressure basis system: ........................................... max. 5076 psi / 350 bar (pressure limiting valve not in scope of delivery)
Operating pressure single-line system: ................................. max. 5076 psi / 350 bar (pressure limiting valve set to 3480 psi / 240 bar)
Operating temperature: ..................................................................... -22°F up to +149°F / -30°C up to +65°C (depending on lubricant)
Number of outlets: ................................................................................................................................................................................... 1
Outlet type: ....................................................................................................................................................................................... G 1/2
Return connection (integrated in pump pipe): .................................................................................................................................. G 1/2
Sound pressure level: ................................................................................................................................................................ <70 dB(A)
Motor
Drive type: ................................................................................................................................................................................... hydraulic
Hydraulic oil inlet: ............................................................................................................................................................................. G 3/8
Hydraulic oil outlet: ........................................................................................................................................................................... G 3/8
Drive pressure (P): ..................................................................................................................................... 290 – 3625 psi / 20 – 250 bar
Return pressure (T): .................................................................................................................................................... max. 43 psi / 3 bar
Volume flow* of the drive medium: ....................................................................................................... 0,53 – 3,2 gal/min / 2 – 12 l/min**
Purity class of the drive medium: ........................................................................................................................... ISO 4406:
≤
21/19/16
1.2 Pump
individually
Weight: ................................................................................................................................................................................ max. 21.3 kg
1.3
Pump – barrel version
Barrel capacity: ..................................................................................................................................................... 213 l (180 kg / 400 lbs)
1.4
Pump – container version
Container capacity: .................................................................................................................... 41 l (60 lbs) / 54 l (90 lbs) / 68 l (120 lbs)
1.5
Solenoid valve – single-line version
Operating voltage: ....................................................................................................................................................................... 24 V DC
Nominal power: ................................................................................................................................................................................. 26 W
Degree of protection: ......................................................................................................................................................................... IP 65
1.6 Level
monitoring
Operating voltage: ......................................................................................................................................................... 10 up to 30 V DC
Electric version: ..................................................................................................................................................................... DC PNP NO
Connection plug: .............................................................................................................................................................. M12x1; 4-poles
Functional principle: ................................................................................................................................................................... ultrasonic
Degree of protection: ......................................................................................................................................................................... IP 67
*
Delivery volume depending on volume flow (see also figure 23 – page 21).
** The volume flow of the drive medium is internally limited to max. 3,2 gal/min / 12 l/min.
Please see the attached data sheets and manuals of the corresponding manufacturers for missing details and further
technical data.
The
barrel pump
is subsequently called a
device.