![BEKA Stream H Original Operating And Assembly Manual Download Page 35](http://html1.mh-extra.com/html/beka/stream-h/stream-h_original-operating-and-assembly-manual_2723986035.webp)
Page
35 ©
BEKA 2019 All rights reserved!
...a product of
14.
Shutdown
Relieve the device from pressure!
Turn off power supply!
A qualified electrician has to disconnect electrical components from the power supply!
Remove all pipes and hoses from the device and loosen all fastenings for disassembly!
15.
Disposal
Observe the disposal instructions of the lubricant manufacturer when lubricant is changed! Lubricants
or cloths contaminated with lubricant, etc. must be collected in specially marked reservoirs and
disposed of accordingly.
Disposal of the device must be done properly and professionally and according to the national and
international laws and regulations.
Moreover, BEKA devices could contain batteries. Professionally and properly disposed batteries will
be recycled. They contain important raw materials.
16.
Troubleshooting
Malfunction
Possible cause
Possible remedy
Pump does not supply
lubricant
Barrel empty
Exchange barrel
Air inclusions in lubricant
Ensure that pump can prime lubricant
Level monitoring
glows
Barrel / container empty
Change barrel / fill up container
Level monitoring
glows, although barrel
is full
Ultrasonic sensor defective
Replace ultrasonic sensor
Supply line to ultrasonic sensor defective Insert new line
No pressure is build
up in pump
Sealing bush of drive piston defective
Renew sealing bush
Suction valve in pump defective or
polluted
Renew or clean suction valve or pump
(see 13.1)
Air inclusions in lubricant
Ensure that pump can prime lubricant
Hydro motor does not
operate
Drive lines interchanged
Connect drive lines correctly
Hydro motor defective
Exchange hydro motor
17.
Spare part list and drawing
Spare part lists and drawings are available on request.