![BEKA Stream H Original Operating And Assembly Manual Download Page 24](http://html1.mh-extra.com/html/beka/stream-h/stream-h_original-operating-and-assembly-manual_2723986024.webp)
Page
24 ©
BEKA 2019 All rights reserved!
...a product of
12.
Maintenance
Disconnect the device from power supply before
maintenance or repair.
Only carry out
maintenance and repair
in
complete
device
standstill
and
pressureless condition
.
Check the surface temperature of the device, as there is the
risk of burns
by radiant heat. Wear heat-resistant gloves
and safety goggles! Clean soiled or contaminated surfaces before maintenance, wearing protective equipment if
necessary! Secure the device against recommissioning during maintenance and repair work!
Further information and technical details regarding the components can be found in the enclosed operating manuals
of the components.
12.1 General
maintenance
Retighten all fittings 6 weeks after start up!
Check all components for leakages and damage at least every four weeks!
If leakages are not repaired, lubricant
might
escape under high pressure
. Remove possible puddles of lubricant
immediately.
12.2 Lubricant
change
Observe utmost
cleanliness
when refilling lubricant!
Check the level regularly and refill clean lubricant as necessary, see chapter start-up.
Change the lubricant according to the specifications of the lubricant manufacturer. Environmental influences like increased
temperature or pollution may shorten these intervals!
Please make sure to only use lubricants that are suitable for the device as well as the lubricated machine and that comply with the
requirements of the particular operating conditions.
In case of
different lubricant manufacturers
, ensure that the lubricant
quality
corresponds to the quality of the previously used
one! As precautionary measure, drain the lubricant reservoir professionally and clean it!
Caution!