12.3 Filling of the container
The pump must be depressurized and secured against unintentional start-up.
Step 1:
Remove the screw plug from the filling connection G1 (fig. 25, pos. 1) (hexagon socket AF 17) and connect a suitable filling pump at
the filling connection G1.
Step 2:
Fill the device slowly with clean lubricant via the filling connection G1 (fig. 25, pos. 1) until lubricant escapes from the overfill protection
(fig. 25, pos. 2). Dispose of leaked lubricant environmentally friendly.
Step 3:
Remove the filling pump again and close the filling connection G1 (fig. 25, pos. 1).
2
3
1
Figure 25