Page
34 ©
BEKA 2019 All rights reserved!
...a product of
Step 12:
For an easier disassembly, the housing cover (N) can be refastened to the pump housing using the 4 cylinder screws (M). Now pull
off the connection body (Q) from the pump housing (O) (figures 49 and 50).
Step 13:
Pull out the sealing bush (R) with a gripper from the connection body (Q) (figure 51).
Now the sealing kit can be replaced by a new one.
Step 14:
Reassemble the device in reverse order.
All seals must fit correctly at installation and must not
be damaged.
Furthermore, the pump housing (O) must be filled
with oil up to the “max. level” (figure 53). Also observe
the notices in step 10.
N
O
Q
Q
R
Caution!
O
Figure 49
Figure 50
Figure 51
Figure 52
Figure 53