9.3.4   Alarm enable:  

EnbL

This  function  allows  the  alarm  to  be  enabled  or
disabled without altering any of the alarm parameters.
Using the 

&

 or 

*

 push button select 

AL1

 or 

AL2

 from

the configuration menu and press   

(  

to access the

alarm sub-menu.  Press the  

&  

or   

*  

button until

EnbL

 is displayed followed by  

(

 which will reveal if

the function is 

on

 or 

off.

  The setting can be changed

by pressing the 

&

 or 

*

 push button followed by the

)

 

button to return to the alarm sub-menu. 

9.3.5  Type of alarm:  

tYPE

Alarm  1  and  Alarm  2  are  totally  independent,  both
may  be  speed  or  run-time  alarms,  or  one  may  be
conditioned for speed and the other for run-time.
Using the 

&

 or 

*

 push button select 

tYPE

 from the

selected alarm sub-menu and press  

(  

to check or

change the function.  The  

&

 or  

*

 push button will

toggle the selection between 

5PEEd

 and 

Hour5

, when

set as required press the  

)  

button to return to the

alarm sub-menu.

Note:

 When

 

tYPE

  is  changed,  the  alarm

configuration  is  automatically  reset  to  the
default values and the alarm is disabled.  It
must therefore be reconfigured before use.

9.3.6  Setpoint adjustment:  

5P1.

x & 

5P2.

x

The  speed  alarm  setpoints  

5P1.5peed

 and  

5P2.5peed

may  be  positioned  anywhere between  

0000000

 and

9999999

,  and  the  run-time  alarm  setpoint  

5P1.Hour5

and  

5P2.Hour5

 anywhere  between  

0000.0

 and  

9999.9

hours.

All   the   setpoints   are   adjusted   in   the   same   way,  for
example, to adjust the setpoint of Alarm 1 which has
been  configured  to  operate  on  the  speed  display.
Using the  

&

 or  

*

 push button select  

5P1.5peed

 in

the 

AL1

 sub-menu and press 

which will reveal the

existing setpoint with one digit flashing.  The required
setpoint  can  be  entered  using  the  

&

 or  

*

 push

button to adjust the flashing digit and the 

button to

transfer  control  to  the  next  digit.      When  set  as
required press 

to enter the value and return to the

5P1.5peed

 prompt in the alarm 1 sub-menu.

9.3.7  Alarm function:  

Hi

 

.

 

Lo

Alarm  1  and  Alarm  2  are  totally  independent,  both
may be Hi or Lo, or one may be conditioned as a Hi
alarm and the other as a Lo alarm.
Using the 

&

 or 

push button select 

Hi

 

.

 

Lo

 from the

selected alarm sub-menu and press  

(  

to check or

change the function.  The  

&

 or  

*

 push button will

toggle the alarm function between  

Hi

 and  

Lo

, when

set as required, press the  

)  

button to return to the

Hi

 

.

 

Lo’ prompt in the alarm sub-menu.

9.3.8  Alarm output status:  

no

 

.

 

nC

Each  single  pole  alarm  output  may  be  open  or
closed  in  the  non-alarm  condition.    When  the
BA314G or BA318E power supply is turned off or
disconnected,  the  alarm  output(s)  will  open
irrespective  of  whether  normally  open  or  normally
closed  outputs  have  been  selected.    Therefore,
when designing an alarm system normally closed 

nc

should be selected so that the output opens when an
alarm occurs or if the power supply fails.

Using the  

&

 or  

*

 push button select  

no

 

.

 

nC

 from

the selected alarm sub-menu and press 

to check

or change the function. The  

&

 or  

*

 push button

will  toggle  the  contact  status  between  

no

 and  

nC

,

when set as required, press the 

button to return

to the 

no

 

.

 

nC

 prompt in the alarm sub-menu 

9.3.9  Hysteresis:  

H5tr

Hysteresis is only available on speed alarms so the

H5tr

 function only appears in the configuration sub-

menu  when  alarm  

tYPE

  has  been  set  to  

5PEEd

.

During configuration hysteresis is shown in the units
of  

5PEED

  previously  configured  for the  Tachometer

display.

Using the  

&

 or  

*

 push button select  

H5tr

 in the

selected alarm sub-menu and press  

(

 which will

reveal the existing hysteresis with one digit flashing.
The  required  hysteresis  can  be  entered  using  the

&

 or 

*

 push button to adjust the flashing digit and

the  

(  

button to transfer control to the next digit.

When set as required press  

)

 to enter the value

and  return  to  the  

H5tr

  prompt  in  the  alarm  sub-

menu.

e.g.  A Tachometer configured to display a rotational
speed of 0 to 500 RPM, with a high alarm set at
400 RPM and hysteresis of 10 RPM will perform as
follows:

The high alarm will be activated when speed
equals or exceeds 400 RPM, but will not reset
until the speed falls below 390 RPM.

9.3.10  Alarm delay:  

dELA

This function enables activation of the alarm output
to be delayed for a fixed time following the alarm
condition  occurring.    The  delay  can  be  set  in  1
second increments up to 3600 seconds.  If a delay is
not required zero should be entered.

To adjust the delay select  

dELA

 using the  

&

 or 

*

push  button  in  the  selected  alarm  sub-menu  and
press 

which will reveal the existing delay time in

seconds with one digit flashing.  The required delay
time can be entered using the 

&

 or 

*

 push button

to  adjust  the  flashing  digit  and  the  

(  

button  to

transfer  control  to  the  next  digit.      When  set  as
required press  

)  

to enter the value and return to

the 

dELA

 prompt in the alarm sub-menu.

37

Summary of Contents for BA314E

Page 1: ...Issue 1 7th February 2017 BA314G and BA314E Intrinsically safe Tachometers Issue 1...

Page 2: ...ns 6 3 Summary of configuration functions 6 4 Input inPut 6 5 Input type inP tYPE 6 6 Debounce dEbouncE 6 7 Display update interval uPdAtE 6 8 Run time display di5P 2 6 9 Position of the decimal point...

Page 3: ...time 5IL 9 3 12 Flash display when alarm occurs FL5H 9 3 13 Access Setpoint AC5P 9 3 14 Adjusting alarm setpoints from the display mode 9 4 4 20mA output 9 4 1 Intrinsic safety 9 4 2 System design 9...

Page 4: ...4...

Page 5: ...A314E only has ATEX gas certification The main sections of this manual describe ATEX gas certification For international applications the BA314G and BA314E also have IECEx certification which is descr...

Page 6: ...fitted A Dual alarm outputs P Pulse output Fitted to all BA314G C 4 20mA output Access to configuration menu Note When optional alarms are fitted the Tachometer may be configured to provide direct acc...

Page 7: ...rt time Be used with gases in groups Group A propane Group B ethylene Group C hydrogen In gases that may be used with equipment having a temperature classification of T1 450 C T2 300 C T3 200 C T4 135...

Page 8: ...Po 0 84W or complies with requirements for simple apparatus b The Sensor and associated wiring can withstand a 500V rms insulation test to earth c The Sensor is located in the same hazardous area as t...

Page 9: ...enclosure It shows the ATEX IECEx and ETL certification information plus BEKA associates name location year of manufacture and the instrument serial number Other certification information may also be...

Page 10: ...barrier the supply voltage in the safe area must be between 15 5V and the maximum working voltage of the Zener barrier which depending upon manufacturer will be approximately 26V Note The optional fac...

Page 11: ...4 1 6 Magnetic pick off input Sensors incorporating a magnetic pick off to sense movement will have a low level voltage output unless the sensor incorporates an amplifier CoiL in the BA314G input conf...

Page 12: ...usly for more than two seconds in the totalising mode i e when the instrument is displaying flow See section 6 15 4 2 Use with Galvanic Isolators Galvanic isolators are probably the simplest intrinsic...

Page 13: ...ector 2k 10k Voltage pulse low 1 0V 3 0V Voltage pulse high 3 0V 10 0V Magnetic pick off 0mV 40mV peak Proximity detector 1 2mA 2 1mA Switch 100 1000 Switch contacts proximity detectors and open colle...

Page 14: ...ge pulse input ranges are independently selectable in the BA314G Tachometer configuration menu VoLt5 L and VoLt5 H When configured for either of the voltage pulse ranges and terminals 3 4 are not link...

Page 15: ...tor An insulated M4 stud is provided in the bottom right hand corner the back box for interconnecting cable screens The BA314G Tachometer may be pipe mounted using a BA393G pipe mounting kit or panel...

Page 16: ...instrument is ordered a blank scale card will be fitted which can easily be marked on site with a dry transfer or a permanent marker Custom printed scale cards are available from BEKA associates as an...

Page 17: ...tor that determines whether the Tachometer displays speed per second per minute or per hour The Tachometer incorporates a run time counter that displays the time in hours that the speed of the monitor...

Page 18: ...on or oFF See section 6 8 Display Summary of function dP Decimal points Defines the position of the decimal point in the Tachometer speed display See section 6 9 5CALE 5 Speed scale factor 5CALE 5 is...

Page 19: ...6 Display Summary of function CLr Gtot Resets grand total run time to zero This function resets the grand total run time to zero from within the configuration menu when CLr YE5 is selected and 5urE is...

Page 20: ...20...

Page 21: ...21...

Page 22: ...Tachometer miscounting when the input pulse has noisy edges such as those resulting from a mechanical contact closing and bouncing Three levels of protection may be selected and the amount of debounc...

Page 23: ...g shaft generates 18 pulses per revolution to produce a Tachometer speed display in revolutions 5CALE 5 should be set to 18 0 The units of the Tachometer speed display are pulses per unit of time The...

Page 24: ...d it is not necessary to enter a clip off value see 6 8 To check or change the clip off threshold select CLP oFF from the configuration menu and press which will reveal the current setting The thresho...

Page 25: ...isplayed and then press which will result in a 0000 prompt being displayed with the first digit flashing This is a request for the instruction to be confirmed by entering 5urE using the or button to a...

Page 26: ...g 11 shows how a 2 channel Zener barrier may be used to produce a voltage pulse in the safe area that could be used to drive a safe area tachometer The positive terminal of the pulse output circuit P1...

Page 27: ...e output pulse with defined duration by the diVidE and durAtion functions Using the or push button select 5ourCE in the pulse output sub menu and press to reveal the existing pulse source The source c...

Page 28: ...ng the or push button to select the required value followed by the button to return to durAtion prompt Note This function only appears in the pulse output sub menu when 5CALEd is selected in the 5ourC...

Page 29: ...between display updates Using the or button select uPdAtE in the configuration menu and press to reveal how frequently the Tachometer display is updated Using the or push button select 0 5 0 5 second...

Page 30: ...h buttons The button will transfer control to the second digit which controls the step response and should be set to 0 in the same way Finally enter the selection and return to the FiLtEr prompt in th...

Page 31: ...ts unauthorised access to the configuration menu Using the or button select CodE from the configuration menu and press which will reveal 0000 with the first digit flashing This example requires the se...

Page 32: ...tion change Re enable both alarms See 9 3 4 8 2 Fault finding after commissioning ENSURE PLANT SAFETY BEFORE STARTING MAINTENANCE Live maintenance is permitted on intrinsically safe equipment installe...

Page 33: ...an be supplied with factory fitted dual isolated solid state single pole alarm outputs that may be independently configured Each may be configured as a speed or run time alarm with a high or low funct...

Page 34: ...r barrier or galvanic isolator providing the output parameters of the circuit do not exceed Uo 28V dc Io 200mA Po 0 84W The maximum equivalent capacitance and inductance between each set of alarm term...

Page 35: ...nt Note 5P15 is displayed for a speed alarm and 5P1H for a run time alarm See section 9 3 6 HI LO Alarm function Defines whether the alarm has a high or low function See section 9 3 7 Display Summary...

Page 36: ...36...

Page 37: ...turn to the Hi Lo prompt in the alarm sub menu 9 3 8 Alarm output status no nC Each single pole alarm output may be open or closed in the non alarm condition When the BA314G or BA318E power supply is...

Page 38: ...ts without having access to the configuration and alarm sub menus Protection against unauthorised or accidental adjustment is provided by a separate security access code Using the or push button selec...

Page 39: ...the or push button and the button to transfer control to the next digit When the required setpoint has been entered pressing will return the display to the 5P1x or 5P2x prompt from which the other se...

Page 40: ...e not powered but it is totally isolated from all other Tachometer circuits It is effectively a 2 wire 4 20mA transmitter requiring a minimum supply of 5V with its current being controlled by the Tac...

Page 41: ...adjust the flashing digit and the button to transfer control to the next digit When set as required press to enter the value and return to the 4 000 prompt in the 4 20mA output sub menu 9 4 7 Display...

Page 42: ...ersist for a short period Be used with dust in subdivisions IIIA combustible flyings IIIB non conductive dust IIIC conductive dust Having a Minimum Ignition Temperature of Dust cloud 120 C Dust layer...

Page 43: ...tification codes Ex ia IIC T5 Ga Ta 40 C to 70 C Ex ia IIIC T80 C IP66 Da Ta 40 C to 60 C The specified IECEx gas and dust intrinsic safety parameters are identical to the ATEX safety parameters descr...

Page 44: ...parameters the systems shown in sections 3 and 4 of this manual may therefore also be used for US and Canadian installations subject to compliance with the local codes of practice ETL and cETL intrin...

Page 45: ...45...

Page 46: ...46...

Page 47: ...47...

Page 48: ...48...

Page 49: ...49...

Page 50: ...50...

Page 51: ...51...

Page 52: ...52...

Page 53: ...53...

Page 54: ...54...

Page 55: ...55...

Page 56: ...56...

Page 57: ...he two mounting holes are located in a separate compartment with a sealed cover allowing the instrument to be installed without exposing the display assembly The enclosure is fitted with a bonding pla...

Page 58: ...d one or both of the IP66 stopping plugs may be replaced with an appropriate IP rated cable gland or conduit fitting d Connect the field wiring to the terminals as shown in Fig A4 2 7 Replace the inst...

Reviews: