PF1352 USER MANUAL REV A 12/21/15
6.3.5 COMMUNICATION TAB
Figure 6-7 shows the Communication Tab, which contains the SCPI commands used to
set up the communication parameters for the Ethernet and RS-232 ports.
All Ethernet and RS-232 parameters are saved in nonvolatile memory. The parameters
are reset to their factory default values after the power supply is powered on in Boot
Loader mode, allowing the user to reset the communication parameters if the power
supply becomes unresponsive after a parameter change. To exit Boot Loader mode
without uploading new firmware, move the external switch to the down position while the
power supply is still powered on. More information regarding the Boot Loader mode can
be found in the Boot Loader section.
Figure 6-7 Communication Tab
More information regarding communication setup commands can be found in the
programming manual for the power supply.
See table 6-1 for the RS-232 and Ethernet factory default settings.