PF1352 USER MANUAL REV A 12/21/15
2.3
AC OUTPUT LOAD CONNECTIONS
Connect the load to the rear panel AC output at TB1. TB1 is marked “H” and, “L”, and
“G” (chassis). Note that this device produces output voltages that are hazardous under
normal conditions. The end user must make sure that all output wiring is installed in a
way that prevents inadvertent contact with operating personnel.
The use of warning
labels is highly recommended.
The output circuit of this device is transformer coupled and floating with respect to the
input line. Either side of the AC output may be tied to earth or other potential. The
maximum continuous floating voltage that can be applied between either output terminal
and ground is 500VDC. Dielectric strength is 1500Vrms for 60 seconds. Refer to figure
2-1 for an illustration of a typical PF series power supply output circuit configuration.
FIGURE 2-1 PF1352 OUTPUT CIRCUIT