Transport and storage
Version: 1.0
───
37
AA3000
6.3
Long-term storage
Observe the maximum storage time
Do not exceed the maximum storage time of two years.
Exceeding the specified maximum storage time can lead to
changes in the properties of the lubricant used and damage the
electric cylinder during subsequent operation.
Perform recurring inspections
Check the motor for proper condition every six months.
Damage to the electric cylinder or maintenance work not carried
out will affect the service life of the installed components and parts.
Prevent the formation of condensation
Keep the ambient temperature constant. Avoid solar radiation and
high air humidity.
Condensation water can lead to damage during subsequent opera-
tion or to rust formation.
You have the option of storing the electric cylinder for a short or
longer period of time. For storage we always recommend the origi-
nal packaging. Adhere to the conditions specified in the chapter:
"Transport and storage", [
The electric cylinders are protected against chemical and aggres-
sive substances through the classes 1C2, chemical substances and
1B2, biological conditions.
Ensure the storage space is vibration-free.