– 107 –
CXD3068Q
Command
Data 1
Audio CTRL
VARI
ON
VARI
USE
Mute
ATT
D23
D22
D21
D20
Data 2
PCT1
PCT2
D19
D18
0
SOC2
D17
D16
$AX commands
Command bit
Mute = 0
Mute = 1
Mute off if other mute
conditions are not set.
Mute on. Peak register reset.
Meaning
Command bit
ATT = 0
ATT = 1
Attenuation off.
–12dB
Meaning
Mute conditions
(1) When register A mute = 1.
(2) When Mute pin = 1.
(3) When register 8 D.out Mute F = 1 and the Digital Out is on (MD2 pin = 1).
(4) When GFS stays low for over 35 ms (during normal-speed).
(5) When register 9 BiliGL MAIN = Sub = 1.
(6) When register A PCT1 = 1 and PCT2 = 0.
(1) to (4) perform zero-cross muting with a 1ms time limit.
Command bit
PCT1
0
0
1
1
PCT2
0
1
0
1
Normal mode
Level meter mode
Peak meter mode
Normal mode
×
0dB
×
0dB
Mute
×
0dB
C1: double; C2: quadruple
C1: double; C2: quadruple
C1: double; C2: double
C1: double; C2: double
Meaning
PCM Gain
ECC error correction ability
Description of level meter mode (see Timing Chart 1-4.)
• When the LSI is set to this mode, it performs digital level meter functions.
• When the 96-bit clock is input to SQCK, 96 bits of data are output to SQSO.
The initial 80 bits are Sub-Q data (see "§ 2. Subcode Interface"). The last 16 bits are LSB first, which are 15-
bit PCM data (absolute values) and an L/R flag.
The L/R flag is high when the 15-bit PCM data is from the left channel and low when the data is from the right
channel.
• The PCM data is reset and the L/R flag is reversed after one readout.
Then maximum value measuring continues until the next readout.
Command bit
VARION = 0
Processing
Variable pitch mode is turned off. (The crystal is the reference to the internal clock.)
Variable pitch mode is turned on. (The VCO2 is the reference to the internal clock.)
VARION = 1
Command bit
VARIUSE = 0
Processing
When the variable pitch mode is not used, set VARIUSE to 0 .
When the variable pitch mode is used, set VARIUSE to 1.
∗
See "$DX commands" for the variable range and the usage example of the variable pitch.
VARIUSE = 1
Summary of Contents for PV420S
Page 1: ...SERVICE MANUAL PV420S WWW BBK RU ...
Page 72: ... 69 CXD3068Q Block Diagram ...
Page 73: ... 70 CXD3068Q Pin Configuration ...
Page 122: ... 119 CXD3068Q Timing Chart 1 3 ...
Page 123: ... 120 CXD3068Q Timing Chart 1 4 ...
Page 124: ... 121 CXD3068Q Timing Chart 1 5 ...
Page 129: ... 126 CXD3068Q Timing Chart 2 1 ...
Page 130: ... 127 CXD3068Q Block Diagram 2 2 ...
Page 131: ... 128 CXD3068Q Timing Chart 2 3 ...
Page 134: ... 131 CXD3068Q Timing Chart 2 6 ...
Page 138: ... 135 CXD3068Q VCO C Mode Fig 3 3 Access Flow Chart Using VCO Control ...
Page 140: ... 137 CXD3068Q Block Diagram 4 1 ...
Page 143: ... 140 CXD3068Q Timing Chart 4 4 ...
Page 147: ... 144 CXD3068Q Fig 4 6 a Auto Focus Flow Chart Fig 4 6 b Auto Focus Timing Chart ...
Page 148: ... 145 CXD3068Q Fig 4 7 a 1 Track Jump Flow Chart Fig 4 7 b 1 Track Jump Timing Chart ...
Page 149: ... 146 CXD3068Q Fig 4 8 a 10 Track Jump Flow Chart Fig 4 8 b 10 Track Jump Timing Chart ...
Page 150: ... 147 CXD3068Q Fig 4 9 a 2N Track Jump Flow Chart Fig 4 9 b 2N Track Jump Timing Chart ...
Page 151: ... 148 CXD3068Q Fig 4 10 a Fine Search Flow Chart Fig 4 10 b Fine Search Timing Chart ...
Page 152: ... 149 CXD3068Q Fig 4 11 a M Track Move Flow Chart Fig 4 11 b M Track Move Timing Chart ...
Page 157: ... 154 CXD3068Q Fig 4 15 CD TEXT Data Timing Chart ...
Page 162: ... 159 CXD3068Q Fig 5 3a Fig 5 3b ...
Page 196: ... 193 CXD3068Q Description of Data Readout ...
Page 200: ... 197 CXD3068Q ...
Page 201: ... 198 CXD3068Q ...
Page 202: ... 199 CXD3068Q ...
Page 207: ... 204 CXD3068Q Package Outline Unit mm ...
Page 208: ...This data sheet has been made from recycled paper to help protect the environment 205 ...