MX08 Multichannel Weighing System, Technical Manual, Rev. 2.5 Page 84 of 144
10.4.1. Profinet Parameters on EtherX
There are 7 parameters for Profinet network.
DHCP
Dynamic Host Configuration Protocol automates network parameters if it is enabled.
Default is ‘Disable’.
IP Address
If DHCP is disabled, obtain IP address manually.
Default is ‘192.168.16.250’.
Subnet Mask
If DHCP is disabled, obtain subnet mask manually.
Default is ‘255.255.255.0’.
Default Gateway
If DHCP is disabled, obtain default gateway manually.
Default is ‘192.168.16.254’.
Primary DNS
If DHCP is disabled, obtain primary DNS manually.
Default is ‘208.67.222.222’.
Secondary DNS
If DHCP is disabled, obtain secondary DNS manually.
Default is ‘208.67.220.220’.
Host Name
Enter a unique host name to the instrument.
Default is ‘ ’.
10.4.2. Profinet Information
xFace Gateway information block in Gateway tab allows the user to know much
information about gateway instrument as in the following;
Field bus: Profinet
Firmware Version: Revision number of firmware
Firmware Date: Generated firmware date
Hardware Version: Revision number of main pcb board.
Serial Number: Instrument’s serial number.
Gateway Status: Follow the status whether the system is proper or not.
GSDML Configuration: Max. quantity of MX08 AD and MX08 IO instruments in the system.